HMS Industrial Networks Anybus-CompactCom 30

 ​View CSAF
1. EXECUTIVE SUMMARY

CVSS v4 6.3
ATTENTION: Exploitable remotely/low attack complexity
Vendor: HMS Industrial Networks
Equipment: Anybus-CompactCom 30
Vulnerability: Cross-site Scripting

2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition, exfiltrate data, or obtain a high degree of control over the device and subsequent systems, including remote code execution.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following versions of Anybus-CompactCom 30, an industrial communication interface, are affected if they include a web server:

Anybus-CompactCom 30: All versions

3.2 Vulnerability Overview
3.2.1 IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION (‘CROSS-SITE SCRIPTING’) CWE-79
The Anybus-CompactCom 30 products are vulnerable to a XSS attack caused by the lack of input sanitation checks. As a consequence, it is possible to insert HTML code into input fields and store the HTML code. The stored HTML code will be embedded in the page and executed by host browser the next time the page is loaded, enabling social engineering attacks.
CVE-2024-6558 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L).
A CVSS v4 score has also been calculated for CVE-2024-6558. A base score of 6.3 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:L/SC:H/SI:H/SA:L).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Sweden

3.4 RESEARCHER
Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA.
4. MITIGATIONS
HMS recommends users implement at least one of the following:

Add password protection to all webpages served by the Anybus-CompactCom 30 module.
Disable or add the option to allow the end-user to disable the webserver in the AnybusCompactCom 30.
Make sure these products are used locally within a secure network utilizing proper network infrastructure controls. This will help ensure that unused or unnecessary protocols from unauthorized sources are blocked.
Ensure that control systems and devices are situated behind firewalls, ensuring their isolation from the corporate network.
Replace the Anybus-CompactCom 30 module with a Anybus-CompactCom 40 module.

For more information see the associated HMS security advisory.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.
5. UPDATE HISTORY

July 11, 2024: Initial Publication 

View CSAF

1. EXECUTIVE SUMMARY

CVSS v4 6.3
ATTENTION: Exploitable remotely/low attack complexity
Vendor: HMS Industrial Networks
Equipment: Anybus-CompactCom 30
Vulnerability: Cross-site Scripting

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition, exfiltrate data, or obtain a high degree of control over the device and subsequent systems, including remote code execution.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Anybus-CompactCom 30, an industrial communication interface, are affected if they include a web server:

Anybus-CompactCom 30: All versions

3.2 Vulnerability Overview

3.2.1 IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION (‘CROSS-SITE SCRIPTING’) CWE-79

The Anybus-CompactCom 30 products are vulnerable to a XSS attack caused by the lack of input sanitation checks. As a consequence, it is possible to insert HTML code into input fields and store the HTML code. The stored HTML code will be embedded in the page and executed by host browser the next time the page is loaded, enabling social engineering attacks.

CVE-2024-6558 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L).

A CVSS v4 score has also been calculated for CVE-2024-6558. A base score of 6.3 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:L/SC:H/SI:H/SA:L).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Sweden

3.4 RESEARCHER

Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA.

4. MITIGATIONS

HMS recommends users implement at least one of the following:

Add password protection to all webpages served by the Anybus-CompactCom 30 module.
Disable or add the option to allow the end-user to disable the webserver in the AnybusCompactCom 30.
Make sure these products are used locally within a secure network utilizing proper network infrastructure controls. This will help ensure that unused or unnecessary protocols from unauthorized sources are blocked.
Ensure that control systems and devices are situated behind firewalls, ensuring their isolation from the corporate network.
Replace the Anybus-CompactCom 30 module with a Anybus-CompactCom 40 module.

For more information see the associated HMS security advisory.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

July 11, 2024: Initial Publication
 Read More

Siemens RUGGEDCOM

 ​As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).View CSAF
1. EXECUTIVE SUMMARY

CVSS v4 8.7
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Siemens
Equipment: RUGGEDCOM
Vulnerabilities: Exposure of Sensitive Information to an Unauthorized Actor, Incorrect Privilege Assignment, Exposure of Sensitive System Information to an Unauthorized Control Sphere

2. RISK EVALUATION
Successful exploitation could allow an attacker to obtain user credentials, the MACSEC key, or create a remote shell to the affected system.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following products of Siemens, are affected:

RUGGEDCOM i800: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM i800NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM i801: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM i801NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM i802: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM i802NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM i803: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM i803NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM M969: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM M969NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM M2100: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM M2100NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM M2200: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM M2200NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RMC30: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RMC30NC: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RMC8388 V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RMC8388 V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RMC8388NC V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RMC8388NC V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RP110: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RP110NC: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS400: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS400NC: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS401: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS401NC: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416NC: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416NCv2 V4.X: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416NCv2 V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278, CVE-2024-39675)
RUGGEDCOM RS416P: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416PNC: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416PNCv2 V4.X: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416PNCv2 V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278, CVE-2024-39675)
RUGGEDCOM RS416Pv2 V4.X: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416Pv2 V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278, CVE-2024-39675)
RUGGEDCOM RS416v2 V4.X: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416v2 V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278, CVE-2024-39675)
RUGGEDCOM RS900: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900 (32M) V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900 (32M) V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RS900G: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900G (32M) V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900G (32M) V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RS900GNC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900GNC(32M) V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900GNC(32M) V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RS900GP: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900GPNC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900L: All versions (CVE-2023-52237)
RUGGEDCOM RS900LNC: All versions (CVE-2023-52237)
RUGGEDCOM RS900M-GETS-C01: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900M-GETS-XX: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900M-STND-C01: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900M-STND-XX: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900MNC-GETS-C01: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900MNC-GETS-XX: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900MNC-STND-XX: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900MNC-STND-XX-C01: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900NC(32M) V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900NC(32M) V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RS900W: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS910: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS910L: All versions (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS910LNC: All versions (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS910NC: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS910W: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS920L: All versions (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS920LNC: All versions (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS920W: All versions (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS930L: All versions (CVE-2023-52237)
RUGGEDCOM RS930LNC: All versions (CVE-2023-52237)
RUGGEDCOM RS930W: All versions (CVE-2023-52237)
RUGGEDCOM RS940G: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS940GNC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS969: All versions (CVE-2023-52237)
RUGGEDCOM RS969NC: All versions (CVE-2023-52237)
RUGGEDCOM RS1600: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS1600F: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS1600FNC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS1600NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS1600T: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS1600TNC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS8000: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS8000A: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS8000ANC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS8000H: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS8000HNC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS8000NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS8000T: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS8000TNC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG907R: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG908C: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG909R: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG910C: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG920P V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG920P V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG920PNC V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG920PNC V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2100: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2100 (32M) V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2100 (32M) V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2100NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2100NC(32M) V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2100NC(32M) V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2100P: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2100PNC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2200: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2200NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2288 V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2288 V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2288NC V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2288NC V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2300 V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2300 V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2300NC V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2300NC V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2300P V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2300P V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2300PNC V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2300PNC V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2488 V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2488 V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2488NC V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2488NC V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSL910: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSL910NC: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RST916C: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RST916P: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RST2228: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2023-52238, CVE-2024-38278)
RUGGEDCOM RST2228P: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2023-52238, CVE-2024-38278)

3.2 Vulnerability Overview
3.2.1 EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200
The web server of the affected devices allow a low privileged user to access hashes and password salts of all system’s users, including admin users. An attacker could use the obtained information to brute force the passwords offline.
CVE-2023-52237 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2023-52237. A base score of 7.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.2 EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200
The web server of the affected systems leaks the MACSEC key in clear text to a logged in user. An attacker with the credentials of a low privileged user could retrieve the MACSEC key and access (decrypt) the ethernet frames sent by authorized recipients.
CVE-2023-52238 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N).
A CVSS v4 score has also been calculated for CVE-2023-52238. A base score of 2.3 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N).
3.2.3 INCORRECT PRIVILEGE ASSIGNMENT CWE-266
The affected products with IP forwarding enabled wrongly make available certain remote services in non-managed VLANs, even if these services are not intentionally activated. An attacker could leverage this vulnerability to create a remote shell to the affected system.
CVE-2024-38278 has been assigned to this vulnerability. A CVSS v3 base score of 6.6 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2024-38278. A base score of 7.5 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.4 EXPOSURE OF SENSITIVE SYSTEM INFORMATION TO AN UNAUTHORIZED CONTROL SPHERE CWE-497
In some configurations, the affected products wrongly enable the Modbus service in non-managed VLANS. Only serial devices are affected by this vulnerability.
CVE-2024-39675 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2024-38278. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Energy, Communications
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER
Stephen Craven reported these vulnerabilities to Siemens.Thomas Riedmaier from Siemens Energy reported these vulnerabilities to Siemens.
4. MITIGATIONS
Siemens has prepared fixed versions and recommends countermeasures for products where fixes are not available.

(CVE-2024-39675) RUGGEDCOM RMC30, RUGGEDCOM RP110, RUGGEDCOM RS400, RUGGEDCOM RS401, RUGGEDCOM RS416, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS910, RUGGEDCOM RS910W, RUGGEDCOM RMC30NC, RUGGEDCOM RP110NC, RUGGEDCOM RS400NC, RUGGEDCOM RS401NC, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS910NC: Update to V4.3.10 or later version
(CVE-2024-39675) RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416PNCv2 V5.X: Update to V5.9.0 or later version
(CVE-2023-52237) RUGGEDCOM i800, RUGGEDCOM i801, RUGGEDCOM i802, RUGGEDCOM i803, RUGGEDCOM M2100, RUGGEDCOM M2200, RUGGEDCOM M969, RUGGEDCOM RMC30, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RP110, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600T, RUGGEDCOM RS400, RUGGEDCOM RS401, RUGGEDCOM RS416, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000H, RUGGEDCOM RS8000T, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910W, RUGGEDCOM RS940G, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2200, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG920P V4.X, RUGGEDCOM i800NC, RUGGEDCOM i801NC, RUGGEDCOM i802NC, RUGGEDCOM i803NC, RUGGEDCOM M2100NC, RUGGEDCOM M2200NC, RUGGEDCOM M969NC, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RP110NC, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400NC, RUGGEDCOM RS401NC, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS910NC, RUGGEDCOM RS940GNC, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG920PNC V4.X: Update to V4.3.10 or later version
(CVE-2023-52237, CVE-2024-38278) RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSL910, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910NC: Update to V5.9.0 or later version
(CVE-2023-52238) RUGGEDCOM RST2228, RUGGEDCOM RST2228P: Update to V5.9.0 or later version
(CVE-2024-39675) RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W: Currently no fix is planned
(CVE-2023-52237) RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS969, RUGGEDCOM RS969NC: Currently no fix is planned

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

(CVE-2023-52237, CVE-2023-52238) Disable the webserver if not required on the affected systems. Restrict the access to Port 80/tcp and 443/tcp to trusted IP address only
(CVE-2024-38278) RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P: For CVE-2024-38278: Disable the IP Forwarding if not required on the affected system. Also note, the IP forwarding is disabled by default
(CVE-2024-39675) RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS400, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W: Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-170375 in HTML and CSAF.
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.
5. UPDATE HISTORY

July 11, 2024: Initial Publication 

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

CVSS v4 8.7
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Siemens
Equipment: RUGGEDCOM
Vulnerabilities: Exposure of Sensitive Information to an Unauthorized Actor, Incorrect Privilege Assignment, Exposure of Sensitive System Information to an Unauthorized Control Sphere

2. RISK EVALUATION

Successful exploitation could allow an attacker to obtain user credentials, the MACSEC key, or create a remote shell to the affected system.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following products of Siemens, are affected:

RUGGEDCOM i800: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM i800NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM i801: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM i801NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM i802: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM i802NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM i803: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM i803NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM M969: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM M969NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM M2100: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM M2100NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM M2200: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM M2200NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RMC30: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RMC30NC: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RMC8388 V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RMC8388 V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RMC8388NC V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RMC8388NC V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RP110: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RP110NC: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS400: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS400NC: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS401: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS401NC: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416NC: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416NCv2 V4.X: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416NCv2 V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278, CVE-2024-39675)
RUGGEDCOM RS416P: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416PNC: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416PNCv2 V4.X: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416PNCv2 V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278, CVE-2024-39675)
RUGGEDCOM RS416Pv2 V4.X: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416Pv2 V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278, CVE-2024-39675)
RUGGEDCOM RS416v2 V4.X: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS416v2 V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278, CVE-2024-39675)
RUGGEDCOM RS900: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900 (32M) V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900 (32M) V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RS900G: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900G (32M) V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900G (32M) V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RS900GNC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900GNC(32M) V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900GNC(32M) V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RS900GP: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900GPNC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900L: All versions (CVE-2023-52237)
RUGGEDCOM RS900LNC: All versions (CVE-2023-52237)
RUGGEDCOM RS900M-GETS-C01: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900M-GETS-XX: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900M-STND-C01: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900M-STND-XX: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900MNC-GETS-C01: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900MNC-GETS-XX: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900MNC-STND-XX: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900MNC-STND-XX-C01: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900NC(32M) V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS900NC(32M) V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RS900W: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS910: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS910L: All versions (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS910LNC: All versions (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS910NC: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS910W: Versions prior to V4.3.10 (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS920L: All versions (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS920LNC: All versions (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS920W: All versions (CVE-2023-52237, CVE-2024-39675)
RUGGEDCOM RS930L: All versions (CVE-2023-52237)
RUGGEDCOM RS930LNC: All versions (CVE-2023-52237)
RUGGEDCOM RS930W: All versions (CVE-2023-52237)
RUGGEDCOM RS940G: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS940GNC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS969: All versions (CVE-2023-52237)
RUGGEDCOM RS969NC: All versions (CVE-2023-52237)
RUGGEDCOM RS1600: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS1600F: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS1600FNC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS1600NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS1600T: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS1600TNC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS8000: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS8000A: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS8000ANC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS8000H: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS8000HNC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS8000NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS8000T: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RS8000TNC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG907R: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG908C: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG909R: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG910C: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG920P V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG920P V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG920PNC V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG920PNC V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2100: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2100 (32M) V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2100 (32M) V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2100NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2100NC(32M) V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2100NC(32M) V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2100P: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2100PNC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2200: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2200NC: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2288 V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2288 V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2288NC V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2288NC V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2300 V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2300 V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2300NC V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2300NC V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2300P V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2300P V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2300PNC V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2300PNC V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2488 V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2488 V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSG2488NC V4.X: Versions prior to V4.3.10 (CVE-2023-52237)
RUGGEDCOM RSG2488NC V5.X: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSL910: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RSL910NC: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RST916C: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RST916P: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2024-38278)
RUGGEDCOM RST2228: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2023-52238, CVE-2024-38278)
RUGGEDCOM RST2228P: Versions prior to V5.9.0 (CVE-2023-52237, CVE-2023-52238, CVE-2024-38278)

3.2 Vulnerability Overview

3.2.1 EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200

The web server of the affected devices allow a low privileged user to access hashes and password salts of all system’s users, including admin users. An attacker could use the obtained information to brute force the passwords offline.

CVE-2023-52237 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2023-52237. A base score of 7.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.2 EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200

The web server of the affected systems leaks the MACSEC key in clear text to a logged in user. An attacker with the credentials of a low privileged user could retrieve the MACSEC key and access (decrypt) the ethernet frames sent by authorized recipients.

CVE-2023-52238 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2023-52238. A base score of 2.3 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N).

3.2.3 INCORRECT PRIVILEGE ASSIGNMENT CWE-266

The affected products with IP forwarding enabled wrongly make available certain remote services in non-managed VLANs, even if these services are not intentionally activated. An attacker could leverage this vulnerability to create a remote shell to the affected system.

CVE-2024-38278 has been assigned to this vulnerability. A CVSS v3 base score of 6.6 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-38278. A base score of 7.5 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.4 EXPOSURE OF SENSITIVE SYSTEM INFORMATION TO AN UNAUTHORIZED CONTROL SPHERE CWE-497

In some configurations, the affected products wrongly enable the Modbus service in non-managed VLANS. Only serial devices are affected by this vulnerability.

CVE-2024-39675 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-38278. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Energy, Communications
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Stephen Craven reported these vulnerabilities to Siemens.
Thomas Riedmaier from Siemens Energy reported these vulnerabilities to Siemens.

4. MITIGATIONS

Siemens has prepared fixed versions and recommends countermeasures for products where fixes are not available.

(CVE-2024-39675) RUGGEDCOM RMC30, RUGGEDCOM RP110, RUGGEDCOM RS400, RUGGEDCOM RS401, RUGGEDCOM RS416, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS910, RUGGEDCOM RS910W, RUGGEDCOM RMC30NC, RUGGEDCOM RP110NC, RUGGEDCOM RS400NC, RUGGEDCOM RS401NC, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS910NC: Update to V4.3.10 or later version
(CVE-2024-39675) RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416PNCv2 V5.X: Update to V5.9.0 or later version
(CVE-2023-52237) RUGGEDCOM i800, RUGGEDCOM i801, RUGGEDCOM i802, RUGGEDCOM i803, RUGGEDCOM M2100, RUGGEDCOM M2200, RUGGEDCOM M969, RUGGEDCOM RMC30, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RP110, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600T, RUGGEDCOM RS400, RUGGEDCOM RS401, RUGGEDCOM RS416, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000H, RUGGEDCOM RS8000T, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910W, RUGGEDCOM RS940G, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2200, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG920P V4.X, RUGGEDCOM i800NC, RUGGEDCOM i801NC, RUGGEDCOM i802NC, RUGGEDCOM i803NC, RUGGEDCOM M2100NC, RUGGEDCOM M2200NC, RUGGEDCOM M969NC, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RP110NC, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400NC, RUGGEDCOM RS401NC, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS910NC, RUGGEDCOM RS940GNC, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG920PNC V4.X: Update to V4.3.10 or later version
(CVE-2023-52237, CVE-2024-38278) RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSL910, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910NC: Update to V5.9.0 or later version
(CVE-2023-52238) RUGGEDCOM RST2228, RUGGEDCOM RST2228P: Update to V5.9.0 or later version
(CVE-2024-39675) RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W: Currently no fix is planned
(CVE-2023-52237) RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS969, RUGGEDCOM RS969NC: Currently no fix is planned

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

(CVE-2023-52237, CVE-2023-52238) Disable the webserver if not required on the affected systems. Restrict the access to Port 80/tcp and 443/tcp to trusted IP address only
(CVE-2024-38278) RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P: For CVE-2024-38278: Disable the IP Forwarding if not required on the affected system. Also note, the IP forwarding is disabled by default
(CVE-2024-39675) RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS400, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W: Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-170375 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

July 11, 2024: Initial Publication
 Read More

Siemens SINEMA Remote Connect Server

 ​As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).View CSAF
1. EXECUTIVE SUMMARY

CVSS v4 8.7
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Siemens
Equipment: SINEMA Remote Connect Server
Vulnerabilities: Command Injection

2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an authenticated attacker to execute arbitrary code with root privileges.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following products of Siemens are affected:

SINEMA Remote Connect Server: All versions

3.2 Vulnerability Overview
3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND (‘COMMAND INJECTION’) CWE-77
Affected applications are vulnerable to command injection due to missing server side input sanitation when loading VxLAN configurations. This could allow an authenticated attacker to execute arbitrary code with root privileges.
CVE-2024-39570 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2024-39570. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.2 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND (‘COMMAND INJECTION’) CWE-77
Affected applications are vulnerable to command injection due to missing server side input sanitation when loading SNMP configurations. This could allow an attacker with the right to modify the SNMP configuration to execute arbitrary code with root privileges.
CVE-2024-39571 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2024-39571. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER
Siemens reported these vulnerabilities to CISA.
4. MITIGATIONS
Siemens recommends users to update to the latest version:

SINEMA Remote Connect Server: Update to V3.2 HF1 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-928781 in HTML and CSAF.
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.
5. UPDATE HISTORY

July 11, 2024: Initial Publication 

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

CVSS v4 8.7
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Siemens
Equipment: SINEMA Remote Connect Server
Vulnerabilities: Command Injection

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an authenticated attacker to execute arbitrary code with root privileges.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following products of Siemens are affected:

SINEMA Remote Connect Server: All versions

3.2 Vulnerability Overview

3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND (‘COMMAND INJECTION’) CWE-77

Affected applications are vulnerable to command injection due to missing server side input sanitation when loading VxLAN configurations. This could allow an authenticated attacker to execute arbitrary code with root privileges.

CVE-2024-39570 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-39570. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.2 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND (‘COMMAND INJECTION’) CWE-77

Affected applications are vulnerable to command injection due to missing server side input sanitation when loading SNMP configurations. This could allow an attacker with the right to modify the SNMP configuration to execute arbitrary code with root privileges.

CVE-2024-39571 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-39571. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens recommends users to update to the latest version:

SINEMA Remote Connect Server: Update to V3.2 HF1 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-928781 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

July 11, 2024: Initial Publication
 Read More

Siemens TIA Portal and SIMATIC STEP 7

 ​As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).View CSAF
1. EXECUTIVE SUMMARY

CVSS v4 7.0
ATTENTION: Low attack complexity
Vendor: Siemens
Equipment: TIA Portal and SIMATIC STEP 7
Vulnerability: Deserialization of Untrusted Data

2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to cause a type confusion and execute arbitrarycode within the affected application.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following products of Siemens, are affected:

Totally Integrated Automation Portal (TIA Portal): All versions
Totally Integrated Automation Portal (TIA Portal) V18: All versions
SIMATIC STEP 7 Safety V18: All versions

3.2 Vulnerability Overview
3.2.1 DESERIALIZATION OF UNTRUSTED DATA CWE-502
Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllableinput. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/enus/visualstudio/code-quality/ca2300.
CVE-2023-32737 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.3 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2023-32737. A base score of 7.0 has been calculated; the CVSS vector string is (CVSS4.0/AV:L/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER
Siemens reported this vulnerability to CISA.
4. MITIGATIONS
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

Totally Integrated Automation Portal (TIA Portal): Update to V18 Update 2 or later version
Totally Integrated Automation Portal (TIA Portal) V18: Update to V18 Update 2 or later version
SIMATIC STEP 7 Safety V18: Update to V18 Update 2 or later version
Avoid uploading PLC software from untrusted devices or MMC cards

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-313039 in HTML and CSAF.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.
5. UPDATE HISTORY

July 11, 2024: Initial Publication 

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

CVSS v4 7.0
ATTENTION: Low attack complexity
Vendor: Siemens
Equipment: TIA Portal and SIMATIC STEP 7
Vulnerability: Deserialization of Untrusted Data

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to cause a type confusion and execute arbitrary
code within the affected application.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following products of Siemens, are affected:

Totally Integrated Automation Portal (TIA Portal): All versions
Totally Integrated Automation Portal (TIA Portal) V18: All versions
SIMATIC STEP 7 Safety V18: All versions

3.2 Vulnerability Overview

3.2.1 DESERIALIZATION OF UNTRUSTED DATA CWE-502

Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable
input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/enus/visualstudio/code-quality/ca2300.

CVE-2023-32737 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.3 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2023-32737. A base score of 7.0 has been calculated; the CVSS vector string is (CVSS4.0/AV:L/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported this vulnerability to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

Totally Integrated Automation Portal (TIA Portal): Update to V18 Update 2 or later version
Totally Integrated Automation Portal (TIA Portal) V18: Update to V18 Update 2 or later version
SIMATIC STEP 7 Safety V18: Update to V18 Update 2 or later version
Avoid uploading PLC software from untrusted devices or MMC cards

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-313039 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.

5. UPDATE HISTORY

July 11, 2024: Initial Publication
 Read More

Siemens SINEMA Remote Connect Server

 ​As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).View CSAF
1. EXECUTIVE SUMMARY

CVSS v4 8.5
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Siemens
Equipment: SINEMA Remote Connect Server
Vulnerabilities: Command Injection

2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an authenticated local attacker to execute arbitrary code with system privileges.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
Siemens reports that the following versions of SINEMA Remote Connect management platform are affected:

SINEMA Remote Connect Client: versions prior to V3.2 HF1

3.2 Vulnerability Overview
3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND (‘COMMAND INJECTION’) CWE-77
The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading VPN configurations. This could allow an authenticated local attacker to execute arbitrary code with system privileges.
CVE-2024-39567 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2024-39567. A base score of 8.5 has been calculated; the CVSS vector string is (CVSS4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.2 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND (‘COMMAND INJECTION’) CWE-77
The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading proxy configurations. This could allow an authenticated local attacker to execute arbitrary code with system privileges.
CVE-2024-39568 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2024-39568. A base score of 8.5 has been calculated; the CVSS vector string is (CVSS4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.3 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND (‘COMMAND INJECTION’) CWE-77
The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading VPN configurations. This could allow an administrative remote attacker running a corresponding SINEMA Remote Connect Server to execute arbitrary code with system privileges on the client system.
CVE-2024-39569 has been assigned to this vulnerability. A CVSS v3 base score of 6.6 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2024-39569. A base score of 7.5 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing, Commercial Facilities, Energy, Food and Agriculture, Healthcare and Public Health, Transportation Systems, Water and Wastewater Systems
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER
Siemens reported these vulnerabilities to CISA.
4. MITIGATIONS
Siemens has released a new version for SINEMA Remote Connect Client and recommends updating to version (V3.2 HF1 or later.
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-868282 in HTML and CSAF.
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.
5. UPDATE HISTORY

July 11, 2024: Initial Publication 

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

CVSS v4 8.5
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Siemens
Equipment: SINEMA Remote Connect Server
Vulnerabilities: Command Injection

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an authenticated local attacker to execute arbitrary code with system privileges.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Siemens reports that the following versions of SINEMA Remote Connect management platform are affected:

SINEMA Remote Connect Client: versions prior to V3.2 HF1

3.2 Vulnerability Overview

3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND (‘COMMAND INJECTION’) CWE-77

The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading VPN configurations. This could allow an authenticated local attacker to execute arbitrary code with system privileges.

CVE-2024-39567 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-39567. A base score of 8.5 has been calculated; the CVSS vector string is (CVSS4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.2 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND (‘COMMAND INJECTION’) CWE-77

The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading proxy configurations. This could allow an authenticated local attacker to execute arbitrary code with system privileges.

CVE-2024-39568 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-39568. A base score of 8.5 has been calculated; the CVSS vector string is (CVSS4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.3 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND (‘COMMAND INJECTION’) CWE-77

The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading VPN configurations. This could allow an administrative remote attacker running a corresponding SINEMA Remote Connect Server to execute arbitrary code with system privileges on the client system.

CVE-2024-39569 has been assigned to this vulnerability. A CVSS v3 base score of 6.6 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-39569. A base score of 7.5 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing, Commercial Facilities, Energy, Food and Agriculture, Healthcare and Public Health, Transportation Systems, Water and Wastewater Systems
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has released a new version for SINEMA Remote Connect Client and recommends updating to version (V3.2 HF1 or later.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-868282 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

July 11, 2024: Initial Publication
 Read More

Rockwell Automation ThinManager ThinServer

 ​View CSAF
1. EXECUTIVE SUMMARY

CVSS v4 9.3
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Rockwell Automation
Equipment: ThinManager ThinServer

Vulnerabilities: Improper Input Validation
2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code or cause a denial-of-service condition.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The vulnerabilities exist in the following versions of ThinManger ThinServer:

ThinManager ThinServer: Versions 11.1.0, 11.2.0, 12.0.0, 12.1.0, 13.0.0, 13.1.0, 13.2.0 (CVE-2024-5988, CVE-2024-5989)
ThinManager ThinServer: Versions 11.1.0, 11.2.0, 12.0.0, 12.1.0, 13.0.0, 13.1.0 (CVE-2024-5990)

3.2 Vulnerability Overview
3.2.1 IMPROPER INPUT VALIDATION CWE-20
Due to an improper input validation, an unauthenticated threat actor can send a malicious message to invoke a local or remote executable and cause a remote code execution condition on the affected device.
CVE-2024-5988 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2024-5988. A base score of 9.3 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.2 IMPROPER INPUT VALIDATION CWE-20
Due to an improper input validation, an unauthenticated threat actor can send a malicious message to invoke SQL injection into the program and cause a remote code execution condition on the affected device.
CVE-2024-5989 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2024-5989. A base score of 9.3 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.3 IMPROPER INPUT VALIDATION CWE-20
Due to an improper input validation, an unauthenticated threat actor can send a malicious message to a monitor thread within ThinServer and cause a denial-of-service condition on the affected device.
CVE-2024-5990 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
A CVSS v4 score has also been calculated for CVE-2024-5990. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER
Rockwell Automation reported these vulnerabilities to CISA.
4. MITIGATIONS
Rockwell Automation has corrected the reported vulnerabilities in the following versions available at the ThinManager download site:11.1.8, 11.2.9 12.0.7, 12.1.8, 13.0.5, 13.1.3, 13.2.2
Rockwell Automation recommends users of the affected software to apply the risk mitigations from the list below. Users are also recommended to implement Rockwell Automation’s suggested security best practices to minimize the potential risk of vulnerability.

Update to the corrected software versions via the ThinManager Downloads Site
Limit remote access for TCP Port 2031 to known thin clients and ThinManager servers.
Security Best Practices

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.
5. UPDATE HISTORY

July 11, 2024: Initial Publication 

View CSAF

1. EXECUTIVE SUMMARY

CVSS v4 9.3
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Rockwell Automation
Equipment: ThinManager ThinServer

Vulnerabilities: Improper Input Validation

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code or cause a denial-of-service condition.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The vulnerabilities exist in the following versions of ThinManger ThinServer:

ThinManager ThinServer: Versions 11.1.0, 11.2.0, 12.0.0, 12.1.0, 13.0.0, 13.1.0, 13.2.0 (CVE-2024-5988, CVE-2024-5989)
ThinManager ThinServer: Versions 11.1.0, 11.2.0, 12.0.0, 12.1.0, 13.0.0, 13.1.0 (CVE-2024-5990)

3.2 Vulnerability Overview

3.2.1 IMPROPER INPUT VALIDATION CWE-20

Due to an improper input validation, an unauthenticated threat actor can send a malicious message to invoke a local or remote executable and cause a remote code execution condition on the affected device.

CVE-2024-5988 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-5988. A base score of 9.3 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.2 IMPROPER INPUT VALIDATION CWE-20

Due to an improper input validation, an unauthenticated threat actor can send a malicious message to invoke SQL injection into the program and cause a remote code execution condition on the affected device.

CVE-2024-5989 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-5989. A base score of 9.3 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.3 IMPROPER INPUT VALIDATION CWE-20

Due to an improper input validation, an unauthenticated threat actor can send a malicious message to a monitor thread within ThinServer and cause a denial-of-service condition on the affected device.

CVE-2024-5990 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2024-5990. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Rockwell Automation reported these vulnerabilities to CISA.

4. MITIGATIONS

Rockwell Automation has corrected the reported vulnerabilities in the following versions available at the ThinManager download site:
11.1.8, 11.2.9 12.0.7, 12.1.8, 13.0.5, 13.1.3, 13.2.2

Rockwell Automation recommends users of the affected software to apply the risk mitigations from the list below. Users are also recommended to implement Rockwell Automation’s suggested security best practices to minimize the potential risk of vulnerability.

Update to the corrected software versions via the ThinManager Downloads Site
Limit remote access for TCP Port 2031 to known thin clients and ThinManager servers.
Security Best Practices

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

July 11, 2024: Initial Publication
 Read More

CISA Releases Twenty-one Industrial Control Systems Advisories

 ​CISA released twenty-one Industrial Control Systems (ICS) advisories on July 11, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS.

ICSA-24-193-01 Siemens Remote Connect Server
ICSA-24-193-02 Siemens RUGGEDCOM APE 1808
ICSA-24-193-03 Siemens Teamcenter Visualization and JT2Go
ICSA-24-193-04 Siemens Simcenter Femap
ICSA-24-193-05 Siemens SCALANCE, RUGGEDCOM, SIPLUS, and SINEC
ICSA-24-193-06 Siemens RUGGEDCOM
ICSA-24-193-07 Siemens SIMATIC and SIMIT
ICSA-24-193-08 Siemens Mendix Encryption Module
ICSA-24-193-09 Siemens SINEMA Remote Connect Server
ICSA-24-193-10 Siemens JT Open and PLM XML SDK
ICSA-24-193-11 Siemens RUGGEDCOM APE 1808
ICSA-24-193-12 Siemens TIA Portal and SIMATIC STEP 7
ICSA-24-193-13 Siemens TIA Portal, SIMATIC, and SIRIUS
ICSA-24-193-14 Siemens SIPROTEC
ICSA-24-193-15 Siemens SINEMA Remote Connect Server
ICSA-24-193-16 Siemens SIMATIC WinCC
ICSA-24-193-17 Siemens SIMATIC STEP 7 (TIA Portal)
ICSA-24-193-18 Rockwell Automation ThinManager ThinServer
ICSA-24-193-19 Rockwell Automation FactoryTalk System Services and Policy Manager
ICSA-24-193-20 HMS Industrial Networks Anybus-CompactCom 30
ICSA-22-356-03 Mitsubishi Electric MELSEC iQ-R, iQ-L Series and MELIPC Series (Update D)

CISA encourages users and administrators to review the newly released ICS advisories for technical details and mitigations. 

CISA released twenty-one Industrial Control Systems (ICS) advisories on July 11, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS.

ICSA-24-193-01 Siemens Remote Connect Server
ICSA-24-193-02 Siemens RUGGEDCOM APE 1808
ICSA-24-193-03 Siemens Teamcenter Visualization and JT2Go
ICSA-24-193-04 Siemens Simcenter Femap
ICSA-24-193-05 Siemens SCALANCE, RUGGEDCOM, SIPLUS, and SINEC
ICSA-24-193-06 Siemens RUGGEDCOM
ICSA-24-193-07 Siemens SIMATIC and SIMIT
ICSA-24-193-08 Siemens Mendix Encryption Module
ICSA-24-193-09 Siemens SINEMA Remote Connect Server
ICSA-24-193-10 Siemens JT Open and PLM XML SDK
ICSA-24-193-11 Siemens RUGGEDCOM APE 1808
ICSA-24-193-12 Siemens TIA Portal and SIMATIC STEP 7
ICSA-24-193-13 Siemens TIA Portal, SIMATIC, and SIRIUS
ICSA-24-193-14 Siemens SIPROTEC
ICSA-24-193-15 Siemens SINEMA Remote Connect Server
ICSA-24-193-16 Siemens SIMATIC WinCC
ICSA-24-193-17 Siemens SIMATIC STEP 7 (TIA Portal)
ICSA-24-193-18 Rockwell Automation ThinManager ThinServer
ICSA-24-193-19 Rockwell Automation FactoryTalk System Services and Policy Manager
ICSA-24-193-20 HMS Industrial Networks Anybus-CompactCom 30
ICSA-22-356-03 Mitsubishi Electric MELSEC iQ-R, iQ-L Series and MELIPC Series (Update D)

CISA encourages users and administrators to review the newly released ICS advisories for technical details and mitigations.

 Read More

Siemens Teamcenter Visualization and JT2Go

 ​As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).View CSAF
1. EXECUTIVE SUMMARY

CVSS v3 7.8
ATTENTION: Low attack complexity
Vendor: Siemens
Equipment: Teamcenter Visualization, JT2Go
Vulnerability: Out-of-bounds Read

2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to execute code in the context of the current process.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following products of Siemens, are affected:

Siemens JT2Go: Versions prior to v14.3.0.8
Siemens Teamcenter Visualization V14.1: Versions prior to v14.1.0.14
Siemens Teamcenter Visualization V14.2: Versions prior to v14.2.0.10
Siemens Teamcenter Visualization V14.3: Versions prior to v14.3.0.8
Siemens Teamcenter Visualization V2312: Versions prior to v2312.0002

3.2 Vulnerability Overview
3.2.1 OUT-OF-BOUNDS READ CWE-125
The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-7066 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER
MoyunSec reported this vulnerability to Siemens.
4. MITIGATIONS
Siemens recommends users update the follow products to the latest versions:

Teamcenter Visualization V14.1: Update to V14.1.0.14 or later version
Teamcenter Visualization V14.2: Update to V14.2.0.10 or later version
JT2Go: Update to V14.3.0.8 or later version
Teamcenter Visualization V14.3: Update to V14.3.0.8 or later version
Teamcenter Visualization V2312: Update to V2312.0002 or later version

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

All affected products: Do not open untrusted PDF files in affected applications.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-722010 in HTML and CSAF.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.
5. UPDATE HISTORY

July 11, 2024: Initial Publication 

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

CVSS v3 7.8
ATTENTION: Low attack complexity
Vendor: Siemens
Equipment: Teamcenter Visualization, JT2Go
Vulnerability: Out-of-bounds Read

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to execute code in the context of the current process.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following products of Siemens, are affected:

Siemens JT2Go: Versions prior to v14.3.0.8
Siemens Teamcenter Visualization V14.1: Versions prior to v14.1.0.14
Siemens Teamcenter Visualization V14.2: Versions prior to v14.2.0.10
Siemens Teamcenter Visualization V14.3: Versions prior to v14.3.0.8
Siemens Teamcenter Visualization V2312: Versions prior to v2312.0002

3.2 Vulnerability Overview

3.2.1 OUT-OF-BOUNDS READ CWE-125

The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.

CVE-2023-7066 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

MoyunSec reported this vulnerability to Siemens.

4. MITIGATIONS

Siemens recommends users update the follow products to the latest versions:

Teamcenter Visualization V14.1: Update to V14.1.0.14 or later version
Teamcenter Visualization V14.2: Update to V14.2.0.10 or later version
JT2Go: Update to V14.3.0.8 or later version
Teamcenter Visualization V14.3: Update to V14.3.0.8 or later version
Teamcenter Visualization V2312: Update to V2312.0002 or later version

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

All affected products: Do not open untrusted PDF files in affected applications.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-722010 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.

5. UPDATE HISTORY

July 11, 2024: Initial Publication
 Read More

Siemens Remote Connect Server

 ​As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).View CSAF
1. EXECUTIVE SUMMARY

CVSS v3 9.6
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Siemens
Equipment: Remote Connect Server
Vulnerabilities: Incorrect User Management, Unrestricted Upload of File with Dangerous Type, Forced Browsing, Improper Check for Unusual or Exceptional Conditions, Client-Side Enforcement of Server-Side Security, Incorrect Authorization, Creation of Temporary File With Insecure Permissions, Improper Restriction of Excessive Authentication Attempts, Incorrect Permission Assignment for Critical Resource, Allocation of Resources Without Limits or Throttling

2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of service condition, learn vulnerable credentials, escalate privileges, modify users outside of scope, gain access to participant groups, use temporary credentials for authentication bypass, or execute arbitrary code.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following products of Siemens, are affected:

Siemens SINEMA Remote Connect Server: All versions prior to V3.2 SP1

3.2 Vulnerability Overview
3.2.1 INCORRECT USER MANAGEMENT CWE-286
The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios.
CVE-2022-32260 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H).
3.2.2 UNRESTRICTED UPLOAD OF FILE WITH DANGEROUS TYPE CWE-434
The affected application allows users to upload encrypted backup files. As part of this backup, files can be restored without correctly checking the path of the restored file. This could allow an attacker with access to the backup encryption key to upload malicious files, that could potentially lead to remote code execution.
CVE-2024-39865 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
3.2.3 PRIVILEGE DEFINED WITH UNSAFE ACTIONS CWE-267
The affected application allows users to upload encrypted backup files. This could allow an attacker with access to the backup encryption key and with the right to upload backup files to create a user with administrative privileges.
CVE-2024-39866 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
3.2.4 DIRECT REQUEST (‘FORCED BROWSING’) CWE-425
Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit device configuration information of devices for which they have no privileges.
CVE-2024-39867 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H).
3.2.5 DIRECT REQUEST (‘FORCED BROWSING’) CWE-425
Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit VxLAN configuration information of networks for which they have no privileges.
CVE-2024-39868 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H).
3.2.6 IMPROPER CHECK FOR UNUSUAL OR EXCEPTIONAL CONDITIONS CWE-754
Affected products allow to upload certificates. An authenticated attacker could upload a crafted certificates leading to a permanent denial-of-service situation. In order to recover from such an attack, the offending certificate needs to be removed manually.
CVE-2024-39869 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H).
3.2.7 CLIENT-SIDE ENFORCEMENT OF SERVER-SIDE SECURITY CWE-602
The affected applications can be configured to allow users to manage own users. A local authenticated user with this privilege could use this modify users outside of their own scope as well as to escalate privileges.
CVE-2024-39870 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L).
3.2.8 INCORRECT AUTHORIZATION CWE-863
Affected applications do not properly separate the rights to edit device settings and to edit settings for communication relations. This could allow an authenticated attacker with the permission to manage devices to gain access to participant groups that the attacked does not belong to.
CVE-2024-39871 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L).
3.2.9 CREATION OF TEMPORARY FILE WITH INSECURE PERMISSIONS CWE-378
The affected application does not properly assign rights to temporary files created during its update process. This could allow an authenticated attacker with the ‘Manage firmware updates’ role to escalate their privileges on the underlying OS level.
CVE-2024-39872 has been assigned to this vulnerability. A CVSS v3 base score of 9.6 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N).
3.2.10 IMPROPER RESTRICTION OF EXCESSIVE AUTHENTICATION ATTEMPTS CWE-307
The affected application does not properly implement brute force protection against user credentials in its web API. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.
CVE-2024-39873 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
3.2.11 IMPROPER RESTRICTION OF EXCESSIVE AUTHENTICATION ATTEMPTS CWE-307
The affected application does not properly implement brute force protection against user credentials in its Client Communication component. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.
CVE-2024-39874 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
3.2.12 INCORRECT PERMISSION ASSIGNMENT FOR CRITICAL RESOURCE CWE-732
The affected application allows authenticated, low privilege users with the ‘Manage own remote connections’ permission to retrieve details about other users and group memberships.
CVE-2024-39875 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N).
3.2.13 ALLOCATION OF RESOURCES WITHOUT LIMITS OR THROTTLING CWE-770
Affected applications do not properly handle log rotation. This could allow an unauthenticated remote attacker to cause a denial of service condition through resource exhaustion on the device.
CVE-2024-39876 has been assigned to this vulnerability. A CVSS v3 base score of 4.0 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing, Energy, Nuclear Reactors, Materials, and Waste
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER
Siemens reported these vulnerabilities to CISA.
4. MITIGATIONS
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

SINEMA Remote Connect Server: Update to V3.2 SP1 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.
For more information see the associated Siemens security advisory SSA-381581 in HTML and CSAF.
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.
5. UPDATE HISTORY

July 11, 2024: Initial Publication 

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

CVSS v3 9.6
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Siemens
Equipment: Remote Connect Server
Vulnerabilities: Incorrect User Management, Unrestricted Upload of File with Dangerous Type, Forced Browsing, Improper Check for Unusual or Exceptional Conditions, Client-Side Enforcement of Server-Side Security, Incorrect Authorization, Creation of Temporary File With Insecure Permissions, Improper Restriction of Excessive Authentication Attempts, Incorrect Permission Assignment for Critical Resource, Allocation of Resources Without Limits or Throttling

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of service condition, learn vulnerable credentials, escalate privileges, modify users outside of scope, gain access to participant groups, use temporary credentials for authentication bypass, or execute arbitrary code.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following products of Siemens, are affected:

Siemens SINEMA Remote Connect Server: All versions prior to V3.2 SP1

3.2 Vulnerability Overview

3.2.1 INCORRECT USER MANAGEMENT CWE-286

The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios.

CVE-2022-32260 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H).

3.2.2 UNRESTRICTED UPLOAD OF FILE WITH DANGEROUS TYPE CWE-434

The affected application allows users to upload encrypted backup files. As part of this backup, files can be restored without correctly checking the path of the restored file. This could allow an attacker with access to the backup encryption key to upload malicious files, that could potentially lead to remote code execution.

CVE-2024-39865 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.3 PRIVILEGE DEFINED WITH UNSAFE ACTIONS CWE-267

The affected application allows users to upload encrypted backup files. This could allow an attacker with access to the backup encryption key and with the right to upload backup files to create a user with administrative privileges.

CVE-2024-39866 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.4 DIRECT REQUEST (‘FORCED BROWSING’) CWE-425

Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit device configuration information of devices for which they have no privileges.

CVE-2024-39867 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H).

3.2.5 DIRECT REQUEST (‘FORCED BROWSING’) CWE-425

Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit VxLAN configuration information of networks for which they have no privileges.

CVE-2024-39868 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H).

3.2.6 IMPROPER CHECK FOR UNUSUAL OR EXCEPTIONAL CONDITIONS CWE-754

Affected products allow to upload certificates. An authenticated attacker could upload a crafted certificates leading to a permanent denial-of-service situation. In order to recover from such an attack, the offending certificate needs to be removed manually.

CVE-2024-39869 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H).

3.2.7 CLIENT-SIDE ENFORCEMENT OF SERVER-SIDE SECURITY CWE-602

The affected applications can be configured to allow users to manage own users. A local authenticated user with this privilege could use this modify users outside of their own scope as well as to escalate privileges.

CVE-2024-39870 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L).

3.2.8 INCORRECT AUTHORIZATION CWE-863

Affected applications do not properly separate the rights to edit device settings and to edit settings for communication relations. This could allow an authenticated attacker with the permission to manage devices to gain access to participant groups that the attacked does not belong to.

CVE-2024-39871 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L).

3.2.9 CREATION OF TEMPORARY FILE WITH INSECURE PERMISSIONS CWE-378

The affected application does not properly assign rights to temporary files created during its update process. This could allow an authenticated attacker with the ‘Manage firmware updates’ role to escalate their privileges on the underlying OS level.

CVE-2024-39872 has been assigned to this vulnerability. A CVSS v3 base score of 9.6 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N).

3.2.10 IMPROPER RESTRICTION OF EXCESSIVE AUTHENTICATION ATTEMPTS CWE-307

The affected application does not properly implement brute force protection against user credentials in its web API. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.

CVE-2024-39873 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

3.2.11 IMPROPER RESTRICTION OF EXCESSIVE AUTHENTICATION ATTEMPTS CWE-307

The affected application does not properly implement brute force protection against user credentials in its Client Communication component. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.

CVE-2024-39874 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

3.2.12 INCORRECT PERMISSION ASSIGNMENT FOR CRITICAL RESOURCE CWE-732

The affected application allows authenticated, low privilege users with the ‘Manage own remote connections’ permission to retrieve details about other users and group memberships.

CVE-2024-39875 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N).

3.2.13 ALLOCATION OF RESOURCES WITHOUT LIMITS OR THROTTLING CWE-770

Affected applications do not properly handle log rotation. This could allow an unauthenticated remote attacker to cause a denial of service condition through resource exhaustion on the device.

CVE-2024-39876 has been assigned to this vulnerability. A CVSS v3 base score of 4.0 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing, Energy, Nuclear Reactors, Materials, and Waste
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

SINEMA Remote Connect Server: Update to V3.2 SP1 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-381581 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

July 11, 2024: Initial Publication
 Read More