Siemens Siveillance Video

 ​As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).
View CSAF
1. EXECUTIVE SUMMARY

CVSS v4 5.5
ATTENTION: Exploitable remotely
Vendor: Siemens
Equipment: Siveillance Video
Vulnerability: Missing Encryption of Sensitive Data

2. RISK EVALUATION
Successful exploitation of this vulnerability could remove password protection from the system configuration files, also affecting backup data sets that were created after the update to V2024 R1.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
Siemens reports that the following products are affected:

Siemens Siveillance Video: Versions V24.1 and later

3.2 VULNERABILITY OVERVIEW
3.2.1 MISSING ENCRYPTION OF SENSITIVE DATA CWE-311
Milestone Systems has discovered a security vulnerability in Milestone XProtect installer that resets system configuration password after the upgrading from older versions using specific installers. The system configuration password is an additional, optional protection that is enabled on the Management Server. To mitigate the issue, we highly recommend updating system configuration password via GUI with a standard procedure. Any system upgraded with 2024 R1 or 2024 R2 release installer is vulnerable to this issue. Systems upgraded from 2023 R3 or older with version 2025 R1 and newer are not affected.
CVE-2025-1688 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:L/I:L/A:L).
A CVSS v4 score has also been calculated for CVE-2025-1688. A base score of 5.5 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:N/VC:L/VI:L/VA:L/SC:H/SI:H/SA:H).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER
Milestone PSIRT reported this vulnerability to Siemens.
4. MITIGATIONS
Siemens has identified the following specific workarounds and mitigations that users can apply to reduce risk:

Siveillance Video: Change the system configuration password settings (see page 268 in “Siveillance Video 2024 R1 Administrator Manual”)
Siveillance Video: Currently no fix is available

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information, see the associated Siemens security advisory SSA-552330 in HTML and CSAF.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity.
5. UPDATE HISTORY

May 20, 2025: Initial Republication of Siemens SSA-552330 

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 5.5
  • ATTENTION: Exploitable remotely
  • Vendor: Siemens
  • Equipment: Siveillance Video
  • Vulnerability: Missing Encryption of Sensitive Data

2. RISK EVALUATION

Successful exploitation of this vulnerability could remove password protection from the system configuration files, also affecting backup data sets that were created after the update to V2024 R1.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Siemens reports that the following products are affected:

  • Siemens Siveillance Video: Versions V24.1 and later

3.2 VULNERABILITY OVERVIEW

3.2.1 MISSING ENCRYPTION OF SENSITIVE DATA CWE-311

Milestone Systems has discovered a security vulnerability in Milestone XProtect installer that resets system configuration password after the upgrading from older versions using specific installers. The system configuration password is an additional, optional protection that is enabled on the Management Server. To mitigate the issue, we highly recommend updating system configuration password via GUI with a standard procedure. Any system upgraded with 2024 R1 or 2024 R2 release installer is vulnerable to this issue. Systems upgraded from 2023 R3 or older with version 2025 R1 and newer are not affected.

CVE-2025-1688 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:L/I:L/A:L).

A CVSS v4 score has also been calculated for CVE-2025-1688. A base score of 5.5 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:N/VC:L/VI:L/VA:L/SC:H/SI:H/SA:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Milestone PSIRT reported this vulnerability to Siemens.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations that users can apply to reduce risk:

  • Siveillance Video: Change the system configuration password settings (see page 268 in “Siveillance Video 2024 R1 Administrator Manual”)
  • Siveillance Video: Currently no fix is available

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information, see the associated Siemens security advisory SSA-552330 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity.

5. UPDATE HISTORY

  • May 20, 2025: Initial Republication of Siemens SSA-552330

 Read More

Schneider Electric Galaxy VS, Galaxy VL, Galaxy VXL

 ​View CSAF
1. EXECUTIVE SUMMARY

CVSS v3 10.0
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Schneider Electric
Equipment: Galaxy VS, Galaxy VL, Galaxy VXL
Vulnerability: Missing Authentication for Critical Function

2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to perform unauthenticated remote code execution.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following versions of Schneider Electric products are affected:

Galaxy VS: All versions
Galaxy VL: All versions
Galaxy VXL: All versions

3.2 VULNERABILITY OVERVIEW
3.2.1 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306
Erlang/OTP is a set of libraries for the Erlang programming language. Prior to versions OTP-27.3.3, OTP-26.2.5.11, and OTP-25.3.2.20, a SSH server may allow an attacker to perform unauthenticated remote code execution (RCE). By exploiting a flaw in SSH protocol message handling, a malicious actor could gain unauthorized access to affected systems and execute arbitrary commands without valid credentials. This issue is patched in versions OTP-27.3.3, OTP-26.2.5.11, and OTP-25.3.2.20. A temporary workaround involves disabling the SSH server or to prevent access via firewall rules.
CVE-2025-32433 has been assigned to this vulnerability. A CVSS v3.1 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Critical Manufacturing, Energy
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: France

3.4 RESEARCHER
Schneider Electric reported this vulnerability to CISA.
4. MITIGATIONS
Schneider Electric is establishing a remediation plan for all future versions of Galaxy VS, Galaxy VL, and Galaxy VXL that will include a fix for this vulnerability. Schneider Electric will update this document when the remediation is available. Until then, users should immediately apply the following mitigations to reduce the risk of exploit:

Log on to the NMC4 via the Web Interface. Once logged into the system, navigate to the Console settings page from the menu bar by selecting Configuration -> Network -> Console -> Access
From the Console setting screen, uncheck the enable SSH/SFTP/SCP check box -> Click Apply
As an alternative, setup network segmentation and implement a firewall to block all unauthorized access to SSH port 22/TCP.
If assistance is needed applying the above mitigation, please contact our technical support team: https://www.se.com/ww/en/work/support/

To learn more, Schneider Electric recommends reviewing the Network Management Card 4 Security Handbook for specific actions available here to secure your devices further: https://www.se.com/us/en/download/document/SPD_CCON-B8EJSJ_EN/
To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp
Schneider Electric strongly recommends the following industry cybersecurity best practices:

Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.
Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.
Place all controllers in locked cabinets and never leave them in the “Program” mode.
Never connect programming software to any network other than the network intended for that device.
Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.
Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.
Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.
When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.

For more information see the associated Schneider Electric CPCERT security advisory SEVD-2025-133-05 Galaxy VS, Galaxy VL, Galaxy VXL – SEVD-2025-133-01 PDF Version, Galaxy VS, Galaxy VL, Galaxy VXL – SEVD-2025-133-01 CSAF Version.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.
5. UPDATE HISTORY

May 20, 2025: Initial Republication of Schneider Electric CPCERT SEVD-2025-133-05 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 10.0
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Schneider Electric
  • Equipment: Galaxy VS, Galaxy VL, Galaxy VXL
  • Vulnerability: Missing Authentication for Critical Function

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to perform unauthenticated remote code execution.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Schneider Electric products are affected:

  • Galaxy VS: All versions
  • Galaxy VL: All versions
  • Galaxy VXL: All versions

3.2 VULNERABILITY OVERVIEW

3.2.1 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306

Erlang/OTP is a set of libraries for the Erlang programming language. Prior to versions OTP-27.3.3, OTP-26.2.5.11, and OTP-25.3.2.20, a SSH server may allow an attacker to perform unauthenticated remote code execution (RCE). By exploiting a flaw in SSH protocol message handling, a malicious actor could gain unauthorized access to affected systems and execute arbitrary commands without valid credentials. This issue is patched in versions OTP-27.3.3, OTP-26.2.5.11, and OTP-25.3.2.20. A temporary workaround involves disabling the SSH server or to prevent access via firewall rules.

CVE-2025-32433 has been assigned to this vulnerability. A CVSS v3.1 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Critical Manufacturing, Energy
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: France

3.4 RESEARCHER

Schneider Electric reported this vulnerability to CISA.

4. MITIGATIONS

Schneider Electric is establishing a remediation plan for all future versions of Galaxy VS, Galaxy VL, and Galaxy VXL that will include a fix for this vulnerability. Schneider Electric will update this document when the remediation is available. Until then, users should immediately apply the following mitigations to reduce the risk of exploit:

  • Log on to the NMC4 via the Web Interface. Once logged into the system, navigate to the Console settings page from the menu bar by selecting Configuration -> Network -> Console -> Access
  • From the Console setting screen, uncheck the enable SSH/SFTP/SCP check box -> Click Apply
  • As an alternative, setup network segmentation and implement a firewall to block all unauthorized access to SSH port 22/TCP.
  • If assistance is needed applying the above mitigation, please contact our technical support team: https://www.se.com/ww/en/work/support/

To learn more, Schneider Electric recommends reviewing the Network Management Card 4 Security Handbook for specific actions available here to secure your devices further: https://www.se.com/us/en/download/document/SPD_CCON-B8EJSJ_EN/

To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp

Schneider Electric strongly recommends the following industry cybersecurity best practices:

  • Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.
  • Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.
  • Place all controllers in locked cabinets and never leave them in the “Program” mode.
  • Never connect programming software to any network other than the network intended for that device.
  • Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.
  • Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.
  • Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.
  • When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.

For more information see the associated Schneider Electric CPCERT security advisory SEVD-2025-133-05 Galaxy VS, Galaxy VL, Galaxy VXL – SEVD-2025-133-01 PDF Version, Galaxy VS, Galaxy VL, Galaxy VXL – SEVD-2025-133-01 CSAF Version.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • May 20, 2025: Initial Republication of Schneider Electric CPCERT SEVD-2025-133-05

 Read More

CISA Releases Thirteen Industrial Control Systems Advisories

 ​CISA released thirteen Industrial Control Systems (ICS) advisories on May 20, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS.

ICSA-25-140-01 ABUP IoT Cloud Platform
ICSA-25-140-02 National Instruments Circuit Design Suite
ICSA-25-140-03 Danfoss AK-SM 8xxA Series
ICSA-25-140-04 Mitsubishi Electric Iconics Digital Solutions and Mitsubishi Electric Products
ICSA-25-140-05 Siemens Siveillance Video
ICSA-25-140-06 Schneider Electric PrismaSeT Active – Wireless Panel Server
ICSA-25-140-07 Schneider Electric Galaxy VS, Galaxy VL, Galaxy VXL
ICSA-25-140-08 Schneider Electric Modicon Controllers
ICSA-25-140-09 AutomationDirect MB-Gateway
ICSA-25-140-10 Vertiv Liebert RDU101 and UNITY
ICSA-25-140-11 Assured Telematics Inc (ATI) Fleet Management System with Geotab Integration 
ICSA-25-037-01 Schneider Electric EcoStruxure Power Monitoring Expert (PME) (Update B)
ICSA-25-023-05 Schneider Electric EcoStruxure Power Build Rapsody (Update A)

CISA encourages users and administrators to review newly released ICS advisories for technical details and mitigations. 

CISA released thirteen Industrial Control Systems (ICS) advisories on May 20, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS.

CISA encourages users and administrators to review newly released ICS advisories for technical details and mitigations.

 Read More

Schneider Electric Modicon Controllers

 ​View CSAF
1. EXECUTIVE SUMMARY

CVSS v4 8.7
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Schneider Electric
Equipment: Modicon Controllers M241/M251/M258/LMC058
Vulnerability: Externally Controlled Reference to a Resource in Another Sphere

2. RISK EVALUATION
Successful exploitation of this vulnerability could cause a loss of confidentiality when an unauthenticated attacker manipulates a controller’s webserver URL to access resources.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
Schneider Electric reports that the following products are affected:

Schneider Electric Modicon Controllers M241: Versions prior to 5.3.12.48
Schneider Electric Modicon Controllers M251: Versions prior to 5.3.12.48
Schneider Electric Modicon Controllers M258: All versions
Schneider Electric Modicon Controllers LMC058: All versions

3.2 VULNERABILITY OVERVIEW
3.2.1 EXTERNALLY CONTROLLED REFERENCE TO A RESOURCE IN ANOTHER SPHERE CWE-610
CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could cause a loss of confidentiality when an unauthenticated attacker manipulates a controller’s webserver URL to access resources.
CVE-2025-2875 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
A CVSS v4 score has also been calculated for CVE-2025-2875. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Critical Manufacturing, Energy
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: France

3.4 RESEARCHER
Loc Nguyen, Dat Phung, Thai Do, and Minh Pham of Unit 515 OPSWAT reported this vulnerability to Schneider Electric.
4. MITIGATIONS
Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk:
Schneider Electric Modicon Controllers M241/M251 versions prior to 5.3.12.48: Version 5.3.12.48 of Modicon Controllers M241/M251 includes a fix for this vulnerability. Please use the following instructions:

Use the Controller Assistant feature of EcoStruxure Automation Expert – Motion V24.1 to update the M241/M251 firmware and perform a reboot.
Please install EcoStruxure Automation Expert – Motion V24.1 via the Schneider Electric Software Installer, available at the following link: https://www.se.com/us/en/product-range/2226-ecostruxuremachine-expert-software/#software-and-firmware
Additional information is available in the Quick Start Guide, chapter “EcoStruxure Automation Expert Platform Installation”.Schneider Electric Modicon Controllers M241/M251 versions prior to 5.3.12.48: If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:
Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks.
Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.
Deactivate the Webserver after use when not needed.
Use encrypted communication links when available.
Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS.
Use VPN (Virtual Private Networks) tunnels if remote access is required.
The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide product specific hardening guidelines. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp

Schneider Electric Modicon Controllers M258/LMC058 all versions: Schneider Electric is establishing a remediation plan for all future versions of Modicon M258/LMC058 that will include a fix for this vulnerability. Schneider Electric will update this document when the remediation is available. Until then, users should immediately apply the following mitigations to reduce the risk of exploit:

Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks.
Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.
Deactivate the Webserver after use when not needed.
Use encrypted communication links when available.
Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS.
Use VPN (Virtual Private Networks) tunnels if remote access is required.
The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon, and PacDrive Controllers and Associated Equipment” provide product specific hardening guidelines. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp

The following product versions have been fixed:

Modicon Controllers M241 version 5.3.12.48 is a fixed version for CVE-2025-2875
Modicon Controllers M251 version 5.3.12.48 is a fixed version for CVE-2025-2875

For more information see the associated Schneider Electric CPCERT security advisory SEVD-2025-133-01 Modicon Controllers M241/M251/M258/LMC058 – SEVD-2025-133-01 PDF Version, Modicon Controllers M241/M251/M258/LMC058 – SEVD-2025-133-01 CSAF Version.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.
5. UPDATE HISTORY

May 20, 2025: Initial Republication of Schneider Electric CPCERT SEVD-2025-133-01 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.7
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Schneider Electric
  • Equipment: Modicon Controllers M241/M251/M258/LMC058
  • Vulnerability: Externally Controlled Reference to a Resource in Another Sphere

2. RISK EVALUATION

Successful exploitation of this vulnerability could cause a loss of confidentiality when an unauthenticated attacker manipulates a controller’s webserver URL to access resources.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Schneider Electric reports that the following products are affected:

  • Schneider Electric Modicon Controllers M241: Versions prior to 5.3.12.48
  • Schneider Electric Modicon Controllers M251: Versions prior to 5.3.12.48
  • Schneider Electric Modicon Controllers M258: All versions
  • Schneider Electric Modicon Controllers LMC058: All versions

3.2 VULNERABILITY OVERVIEW

3.2.1 EXTERNALLY CONTROLLED REFERENCE TO A RESOURCE IN ANOTHER SPHERE CWE-610

CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could cause a loss of confidentiality when an unauthenticated attacker manipulates a controller’s webserver URL to access resources.

CVE-2025-2875 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2025-2875. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Critical Manufacturing, Energy
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: France

3.4 RESEARCHER

Loc Nguyen, Dat Phung, Thai Do, and Minh Pham of Unit 515 OPSWAT reported this vulnerability to Schneider Electric.

4. MITIGATIONS

Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk:

Schneider Electric Modicon Controllers M241/M251 versions prior to 5.3.12.48: Version 5.3.12.48 of Modicon Controllers M241/M251 includes a fix for this vulnerability. Please use the following instructions:

  • Use the Controller Assistant feature of EcoStruxure Automation Expert – Motion V24.1 to update the M241/M251 firmware and perform a reboot.
  • Please install EcoStruxure Automation Expert – Motion V24.1 via the Schneider Electric Software Installer, available at the following link: https://www.se.com/us/en/product-range/2226-ecostruxuremachine-expert-software/#software-and-firmware
  • Additional information is available in the Quick Start Guide, chapter “EcoStruxure Automation Expert Platform Installation”.
    Schneider Electric Modicon Controllers M241/M251 versions prior to 5.3.12.48: If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:
  • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks.
  • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.
  • Deactivate the Webserver after use when not needed.
  • Use encrypted communication links when available.
  • Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS.
  • Use VPN (Virtual Private Networks) tunnels if remote access is required.
  • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide product specific hardening guidelines. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp

Schneider Electric Modicon Controllers M258/LMC058 all versions: Schneider Electric is establishing a remediation plan for all future versions of Modicon M258/LMC058 that will include a fix for this vulnerability. Schneider Electric will update this document when the remediation is available. Until then, users should immediately apply the following mitigations to reduce the risk of exploit:

  • Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks.
  • Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use.
  • Deactivate the Webserver after use when not needed.
  • Use encrypted communication links when available.
  • Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS.
  • Use VPN (Virtual Private Networks) tunnels if remote access is required.
  • The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon, and PacDrive Controllers and Associated Equipment” provide product specific hardening guidelines. To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp

The following product versions have been fixed:

  • Modicon Controllers M241 version 5.3.12.48 is a fixed version for CVE-2025-2875
  • Modicon Controllers M251 version 5.3.12.48 is a fixed version for CVE-2025-2875

For more information see the associated Schneider Electric CPCERT security advisory SEVD-2025-133-01 Modicon Controllers M241/M251/M258/LMC058 – SEVD-2025-133-01 PDF Version, Modicon Controllers M241/M251/M258/LMC058 – SEVD-2025-133-01 CSAF Version.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • May 20, 2025: Initial Republication of Schneider Electric CPCERT SEVD-2025-133-01

 Read More

Schneider Electric PrismaSeT Active – Wireless Panel Server

 ​View CSAF
1. EXECUTIVE SUMMARY

CVSS v3 9.8
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Schneider Electric
Equipment: PrismaSeT Active – Wireless Panel Server
Vulnerability: Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’)

2. RISK EVALUATION
Successful exploitation of this vulnerability could allow unauthorized code execution, which could result in the unavailability of the PrismaSeT Active – Wireless Panel Server for voltage loss monitoring.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following versions of Schneider Electric products are affected:

PrismaSeT Active – Wireless Panel Server: All versions

3.2 VULNERABILITY OVERVIEW
3.2.1 BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (‘CLASSIC BUFFER OVERFLOW’) CWE-120
Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’), Out-of-bounds Write, Download of Code Without Integrity Check vulnerability in Silicon Labs Gecko Bootloader on ARM (Firmware Update File Parser modules) allows Code Injection, Authentication Bypass.This issue affects “Standalone” and “Application” versions of Gecko Bootloader.
CVE-2023-4041 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Critical Manufacturing, Energy
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: France

3.4 RESEARCHER
Schneider Electric reported this vulnerability to CISA.
4. MITIGATIONS
PrismaSeT Active – Wireless Panel Server product has reached its end of life and is no longer supported.
Users should immediately apply the following mitigations to reduce the risk of exploit:

Deactivate Bluetooth Low (BLE) communication of Wireless Panel Server when it is not in use.
Periodically review audit logs and/or EcoStruxure Facility Expert App security notifications to detect unexpected behaviors.
Regularly check the physical security of the Wireless Panel Server to protect against unauthorized Bluetooth pairing.
Use only Schneider Electric official EcoStruxure Power Commission App and EcoStruxure Facility Expert App available in Google Play Store and Apple App Store.
Do not use EcoStruxure Power Commission App and EcoStruxure Facility Expert App in rooted or jail-broken mobile devices.
Follow PrismaSeT Active – Wireless Panel Server Cybersecurity Recommendations.

To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/security-notifications.jsp
Schneider Electric strongly recommends the following industry cybersecurity best practices:

Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.
Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.
Place all controllers in locked cabinets and never leave them in the “Program” mode.
Never connect programming software to any network other than the network intended for that device.
Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.
Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.
Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.
When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.

For more information see the associated Schneider Electric CPCERT security advisory SEVD-2025-133-04 PrismaSeT Active – Wireless Panel Server – SEVD-2025-133-04 PDF Version, PrismaSeT Active – Wireless Panel Server – SEVD-2025-133-04 CSAF Version.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.
5. UPDATE HISTORY

May 20, 2025: Initial Republication of Schneider Electric CPCERT SEVD-2025-133-04 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 9.8
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Schneider Electric
  • Equipment: PrismaSeT Active – Wireless Panel Server
  • Vulnerability: Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’)

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow unauthorized code execution, which could result in the unavailability of the PrismaSeT Active – Wireless Panel Server for voltage loss monitoring.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Schneider Electric products are affected:

  • PrismaSeT Active – Wireless Panel Server: All versions

3.2 VULNERABILITY OVERVIEW

3.2.1 BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (‘CLASSIC BUFFER OVERFLOW’) CWE-120

Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’), Out-of-bounds Write, Download of Code Without Integrity Check vulnerability in Silicon Labs Gecko Bootloader on ARM (Firmware Update File Parser modules) allows Code Injection, Authentication Bypass.This issue affects “Standalone” and “Application” versions of Gecko Bootloader.

CVE-2023-4041 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Critical Manufacturing, Energy
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: France

3.4 RESEARCHER

Schneider Electric reported this vulnerability to CISA.

4. MITIGATIONS

PrismaSeT Active – Wireless Panel Server product has reached its end of life and is no longer supported.

Users should immediately apply the following mitigations to reduce the risk of exploit:

  • Deactivate Bluetooth Low (BLE) communication of Wireless Panel Server when it is not in use.
  • Periodically review audit logs and/or EcoStruxure Facility Expert App security notifications to detect unexpected behaviors.
  • Regularly check the physical security of the Wireless Panel Server to protect against unauthorized Bluetooth pairing.
  • Use only Schneider Electric official EcoStruxure Power Commission App and EcoStruxure Facility Expert App available in Google Play Store and Apple App Store.
  • Do not use EcoStruxure Power Commission App and EcoStruxure Facility Expert App in rooted or jail-broken mobile devices.
  • Follow PrismaSeT Active – Wireless Panel Server Cybersecurity Recommendations.

To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/security-notifications.jsp

Schneider Electric strongly recommends the following industry cybersecurity best practices:

  • Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.
  • Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.
  • Place all controllers in locked cabinets and never leave them in the “Program” mode.
  • Never connect programming software to any network other than the network intended for that device.
  • Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.
  • Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.
  • Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.
  • When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.

For more information see the associated Schneider Electric CPCERT security advisory SEVD-2025-133-04 PrismaSeT Active – Wireless Panel Server – SEVD-2025-133-04 PDF Version, PrismaSeT Active – Wireless Panel Server – SEVD-2025-133-04 CSAF Version.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • May 20, 2025: Initial Republication of Schneider Electric CPCERT SEVD-2025-133-04

 Read More

Assured Telematics Inc (ATI) Fleet Management System with Geotab Integration

 ​View CSAF
1. EXECUTIVE SUMMARY

CVSS v4 8.7
ATTENTION: Exploitable remotely/Low attack complexity
Vendor: Assured Telematics Inc.
Equipment: Fleet Management System
Vulnerabilities: Exposure of Sensitive System Information to an Unauthorized Control Sphere

2. RISK EVALUATION
Successful exploitation of this vulnerability could result in an attacker collecting sensitive file system information or obtain administrative credentials.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following product is affected:

Fleet Management System: Versions prior to February 6th, 2025

3.2 VULNERABILITY OVERVIEW
3.2.1 EXPOSURE OF SENSITIVE SYSTEM INFORMATION TO AN UNAUTHORIZED CONTROL SPHERE CWE-497
The affected products could allow an unauthenticated attacker to access system information that could enable further access to sensitive files and obtain administrative credentials.
CVE-2025-4364 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
A CVSS v4 score has also been calculated for CVE-2025-4364. A base score of 8.7 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Transportation Systems
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER
Nicholas Michael Kloster reported this vulnerability to CISA.
4. MITIGATIONS
Assured Telematics reports that they have fixed the exposure of sensitive information.
Contact Assured Telematics for more information
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.
5. UPDATE HISTORY

May 20, 2025: Initial Publication 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.7
  • ATTENTION: Exploitable remotely/Low attack complexity
  • Vendor: Assured Telematics Inc.
  • Equipment: Fleet Management System
  • Vulnerabilities: Exposure of Sensitive System Information to an Unauthorized Control Sphere

2. RISK EVALUATION

Successful exploitation of this vulnerability could result in an attacker collecting sensitive file system information or obtain administrative credentials.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following product is affected:

  • Fleet Management System: Versions prior to February 6th, 2025

3.2 VULNERABILITY OVERVIEW

3.2.1 EXPOSURE OF SENSITIVE SYSTEM INFORMATION TO AN UNAUTHORIZED CONTROL SPHERE CWE-497

The affected products could allow an unauthenticated attacker to access system information that could enable further access to sensitive files and obtain administrative credentials.

CVE-2025-4364 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2025-4364. A base score of 8.7 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Transportation Systems
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Nicholas Michael Kloster reported this vulnerability to CISA.

4. MITIGATIONS

Assured Telematics reports that they have fixed the exposure of sensitive information.

Contact Assured Telematics for more information

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • May 20, 2025: Initial Publication

 Read More

ABUP IoT Cloud Platform

 ​View CSAF
1. EXECUTIVE SUMMARY

CVSS v4 5.9
ATTENTION: Exploitable remotely/Low attack complexity
Vendor: ABUP
Equipment: ABUP Internet of Things (IoT) Cloud Platform
Vulnerability: Incorrect Privilege Assignment

2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to access device profiles for which they are not authorized.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following ABUP products are affected:

ABUP IoT Cloud Platform: All Versions

3.2 VULNERABILITY OVERVIEW
3.2.1 INCORRECT PRIVILEGE ASSIGNMENT CWE-266
Actors can use a maliciously crafted JavaScript Object Notation (JSON) Web Token (JWT) to perform privilege escalation by submitting the malicious JWT to a vulnerable method exposed on the cloud platform. If the exploit is successful, the user can escalate privileges to access any device managed by the Cloud Update Platform.
CVE-2025-4692 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:L/A:L).
A CVSS v4 score has also been calculated for CVE-2025-4692. A base score of 5.9 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:P/PR:L/UI:P/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Communications
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: China

3.4 RESEARCHER
Daniel Christensen of Telenor reported this vulnerability to CISA
4. MITIGATIONS
ABUP did not respond to CISA’s request for coordination.
The vulnerable method has been removed by the vendor and is no longer accessible. Users of the cloud platform do not need to take any action. Legitimate users of the cloud update platform should be aware that there was a period of exposure that ended on 19 April 2025 and should consider modifying authentication information.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to for tracking and correlation against other incidents.
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.
5. UPDATE HISTORY

May 20, 2025: Initial Publication 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 5.9
  • ATTENTION: Exploitable remotely/Low attack complexity
  • Vendor: ABUP
  • Equipment: ABUP Internet of Things (IoT) Cloud Platform
  • Vulnerability: Incorrect Privilege Assignment

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to access device profiles for which they are not authorized.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following ABUP products are affected:

  • ABUP IoT Cloud Platform: All Versions

3.2 VULNERABILITY OVERVIEW

3.2.1 INCORRECT PRIVILEGE ASSIGNMENT CWE-266

Actors can use a maliciously crafted JavaScript Object Notation (JSON) Web Token (JWT) to perform privilege escalation by submitting the malicious JWT to a vulnerable method exposed on the cloud platform. If the exploit is successful, the user can escalate privileges to access any device managed by the Cloud Update Platform.

CVE-2025-4692 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:L/A:L).

A CVSS v4 score has also been calculated for CVE-2025-4692. A base score of 5.9 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:P/PR:L/UI:P/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Communications
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: China

3.4 RESEARCHER

Daniel Christensen of Telenor reported this vulnerability to CISA

4. MITIGATIONS

ABUP did not respond to CISA’s request for coordination.

The vulnerable method has been removed by the vendor and is no longer accessible. Users of the cloud platform do not need to take any action. Legitimate users of the cloud update platform should be aware that there was a period of exposure that ended on 19 April 2025 and should consider modifying authentication information.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • May 20, 2025: Initial Publication

 Read More

AutomationDirect MB-Gateway

 ​View CSAF
1. EXECUTIVE SUMMARY

CVSS v4 10.0
ATTENTION: Exploitable remotely/low attack complexity
Vendor: AutomationDirect
Equipment: MB-Gateway
Vulnerability: Missing Authentication For Critical Function

2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to make configuration changes, disrupt operations, or achieve arbitrary code execution.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following AutomationDirect product is affected:

MB-Gateway: All Versions

3.2 VULNERABILITY OVERVIEW
3.2.1 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306
The embedded webserver lacks authentication and access controls, allowing unrestricted remote access. This could lead to configuration changes, operational disruption, or arbitrary code execution depending on the environment and exposed functionality.
CVE-2025-36535 has been assigned to this vulnerability. A CVSS v3.1 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2025-36535. A base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER
Souvik Kandar reported this vulnerability to AutomationDirect.AutomationDirect reported this vulnerability to CISA.
4. MITIGATIONS
The hardware limitation of MB-Gateway does not provide for the implementation of proper access control update. AutomationDirect recommends that users plan for replacement of MB-Gateway with EKI-1221-CE.
If an immediate replacement is not feasible, AutomationDirect recommends considering the following interim steps until the programming software can be updated:

Restrict network exposure: Ensure devices affected are not accessible from the Internet or untrusted networks. Place them behind firewalls.
Use dedicated, secure internal networks or air-gapped systems for communication with programmable devices.
Control Access: Restrict physical and logical access to authorized personnel only.
Implement Whitelisting: Use application whitelisting to allow only pre-approved and trusted access. Block untrusted or unauthorized applications.
Monitor and Log Activity: Enable logging and monitoring of system activities to detect potential anomalies or unauthorized actions. Regularly review logs for suspicious activity.
Use Secure Backup and Recovery: Regularly back up the workstation and its configurations to a secure location. Test recovery procedures to ensure minimal downtime in the event of an incident.
Plan for device replacement: Organizations should begin evaluating and migrating to supported hardware with active vendor support.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.
5. UPDATE HISTORY

May 20, 2025: Initial Publication 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 10.0
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: AutomationDirect
  • Equipment: MB-Gateway
  • Vulnerability: Missing Authentication For Critical Function

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to make configuration changes, disrupt operations, or achieve arbitrary code execution.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following AutomationDirect product is affected:

  • MB-Gateway: All Versions

3.2 VULNERABILITY OVERVIEW

3.2.1 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306

The embedded webserver lacks authentication and access controls, allowing unrestricted remote access. This could lead to configuration changes, operational disruption, or arbitrary code execution depending on the environment and exposed functionality.

CVE-2025-36535 has been assigned to this vulnerability. A CVSS v3.1 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-36535. A base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Souvik Kandar reported this vulnerability to AutomationDirect.
AutomationDirect reported this vulnerability to CISA.

4. MITIGATIONS

The hardware limitation of MB-Gateway does not provide for the implementation of proper access control update. AutomationDirect recommends that users plan for replacement of MB-Gateway with EKI-1221-CE.

If an immediate replacement is not feasible, AutomationDirect recommends considering the following interim steps until the programming software can be updated:

  • Restrict network exposure: Ensure devices affected are not accessible from the Internet or untrusted networks. Place them behind firewalls.
  • Use dedicated, secure internal networks or air-gapped systems for communication with programmable devices.
  • Control Access: Restrict physical and logical access to authorized personnel only.
  • Implement Whitelisting: Use application whitelisting to allow only pre-approved and trusted access. Block untrusted or unauthorized applications.
  • Monitor and Log Activity: Enable logging and monitoring of system activities to detect potential anomalies or unauthorized actions. Regularly review logs for suspicious activity.
  • Use Secure Backup and Recovery: Regularly back up the workstation and its configurations to a secure location. Test recovery procedures to ensure minimal downtime in the event of an incident.
  • Plan for device replacement: Organizations should begin evaluating and migrating to supported hardware with active vendor support.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • May 20, 2025: Initial Publication

 Read More

National Instruments Circuit Design Suite

 ​View CSAF
1. EXECUTIVE SUMMARY

CVSS v4 8.4
ATTENTION: Low attack complexity
Vendor: National Instruments
Equipment: Circuit Design Suite
Vulnerabilities: Out-of-bounds Write, Out-of-bounds Read, Stack-based Buffer Overflow

2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an attacker to disclose information or execute arbitrary code.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following National Instruments products are affected:

Circuit Design Suite: Versions 14.3.0 and prior

3.2 VULNERABILITY OVERVIEW
3.2.1 OUT-OF-BOUNDS WRITE CWE-787
An out-of-bounds write vulnerability in DecodeBase64() within Circuit Design Suite, caused by improper input validation, may result in arbitrary code execution. To exploit this flaw, an attacker must trick a user into opening a specially crafted SYM file.
CVE-2025-30417 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2025-30417. A base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.2 OUT-OF-BOUNDS WRITE CWE-787
An out-of-bounds write vulnerability in CheckPins() within Circuit Design Suite, caused by improper input validation, may result in arbitrary code execution. To exploit this flaw, an attacker must trick a user into opening a specially crafted SYM file.
CVE-2025-30418 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2025-30418. A base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.3 OUT-OF-BOUNDS READ CWE-125
An out-of-bounds read vulnerability in GetSymbolBorderRectSize() within Circuit Design Suite, caused by improper input validation, may result in information disclosure or arbitrary code execution. To exploit this flaw, an attacker must trick a user into opening a specially crafted SYM file.
CVE-2025-30419 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2025-30419. A base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.4 OUT-OF-BOUNDS READ CWE-125
An out-of-bounds read vulnerability in InternalDraw within Circuit Design Suite, caused by improper input validation, may result in information disclosure or arbitrary code execution. To exploit this flaw, an attacker must trick a user into opening a specially crafted SYM file.
CVE-2025-30420 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2025-30420. A base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.5 STACK-BASED BUFFER OVERFLOW CWE-121
A stack-based buffer overflow vulnerability within Circuit Design Suite, caused by improper input validation, may result in arbitrary code execution. To exploit this flaw, an attacker must trick a user into opening a specially crafted SYM file.
CVE-2025-30421 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2025-30421. A base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Communications, Defense Industrial Base, Government Services and Facilities
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER
Michael Heinzl reported these vulnerabilities to CISA.
4. MITIGATIONS
National Instruments recommends users update to version 14.3.1 or later.
Please see National Instruments security update for more information.
CISA recommends users take defensive measures to minimize the risk of exploitation of this these vulnerabilities, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.
5. UPDATE HISTORY

May 20, 2025: Initial Publication 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.4
  • ATTENTION: Low attack complexity
  • Vendor: National Instruments
  • Equipment: Circuit Design Suite
  • Vulnerabilities: Out-of-bounds Write, Out-of-bounds Read, Stack-based Buffer Overflow

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to disclose information or execute arbitrary code.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following National Instruments products are affected:

  • Circuit Design Suite: Versions 14.3.0 and prior

3.2 VULNERABILITY OVERVIEW

3.2.1 OUT-OF-BOUNDS WRITE CWE-787

An out-of-bounds write vulnerability in DecodeBase64() within Circuit Design Suite, caused by improper input validation, may result in arbitrary code execution. To exploit this flaw, an attacker must trick a user into opening a specially crafted SYM file.

CVE-2025-30417 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-30417. A base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.2 OUT-OF-BOUNDS WRITE CWE-787

An out-of-bounds write vulnerability in CheckPins() within Circuit Design Suite, caused by improper input validation, may result in arbitrary code execution. To exploit this flaw, an attacker must trick a user into opening a specially crafted SYM file.

CVE-2025-30418 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-30418. A base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.3 OUT-OF-BOUNDS READ CWE-125

An out-of-bounds read vulnerability in GetSymbolBorderRectSize() within Circuit Design Suite, caused by improper input validation, may result in information disclosure or arbitrary code execution. To exploit this flaw, an attacker must trick a user into opening a specially crafted SYM file.

CVE-2025-30419 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-30419. A base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.4 OUT-OF-BOUNDS READ CWE-125

An out-of-bounds read vulnerability in InternalDraw within Circuit Design Suite, caused by improper input validation, may result in information disclosure or arbitrary code execution. To exploit this flaw, an attacker must trick a user into opening a specially crafted SYM file.

CVE-2025-30420 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-30420. A base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.5 STACK-BASED BUFFER OVERFLOW CWE-121

A stack-based buffer overflow vulnerability within Circuit Design Suite, caused by improper input validation, may result in arbitrary code execution. To exploit this flaw, an attacker must trick a user into opening a specially crafted SYM file.

CVE-2025-30421 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-30421. A base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Communications, Defense Industrial Base, Government Services and Facilities
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Michael Heinzl reported these vulnerabilities to CISA.

4. MITIGATIONS

National Instruments recommends users update to version 14.3.1 or later.

Please see National Instruments security update for more information.

CISA recommends users take defensive measures to minimize the risk of exploitation of this these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • May 20, 2025: Initial Publication

 Read More

CISA Adds Six Known Exploited Vulnerabilities to Catalog

 ​CISA has added six new vulnerabilities to its Known Exploited Vulnerabilities Catalog, based on evidence of active exploitation. 

CVE-2025-4427 Ivanti Endpoint Manager Mobile (EPMM) Authentication Bypass Vulnerability
CVE-2025-4428 Ivanti Endpoint Manager Mobile (EPMM) Code Injection Vulnerability
CVE-2024-11182 MDaemon Email Server Cross-Site Scripting (XSS) Vulnerability
CVE-2025-27920 Srimax Output Messenger Directory Traversal Vulnerability
CVE-2024-27443 Synacor Zimbra Collaboration Suite (ZCS) Cross-Site Scripting (XSS) Vulnerability
CVE-2023-38950 ZKTeco BioTime Path Traversal Vulnerability

These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. 
Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the Known Exploited Vulnerabilities Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. 
Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. 

CISA has added six new vulnerabilities to its Known Exploited Vulnerabilities Catalog, based on evidence of active exploitation. 

  • CVE-2025-4427 Ivanti Endpoint Manager Mobile (EPMM) Authentication Bypass Vulnerability
  • CVE-2025-4428 Ivanti Endpoint Manager Mobile (EPMM) Code Injection Vulnerability
  • CVE-2024-11182 MDaemon Email Server Cross-Site Scripting (XSS) Vulnerability
  • CVE-2025-27920 Srimax Output Messenger Directory Traversal Vulnerability
  • CVE-2024-27443 Synacor Zimbra Collaboration Suite (ZCS) Cross-Site Scripting (XSS) Vulnerability
  • CVE-2023-38950 ZKTeco BioTime Path Traversal Vulnerability

These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. 

Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the Known Exploited Vulnerabilities Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. 

Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

 Read More