Bug Left Some Windows PCs Dangerously Unpatched

​Microsoft Corp. today released updates to fix at least 79 security vulnerabilities in its Windows operating systems and related software, including multiple flaws that are already showing up in active attacks. Microsoft also corrected a critical bug that has caused some Windows 10 PCs to remain dangerously unpatched against actively exploited vulnerabilities for several months this year. 

Microsoft Corp. today released updates to fix at least 79 security vulnerabilities in its Windows operating systems and related software, including multiple flaws that are already showing up in active attacks. Microsoft also corrected a critical bug that has caused some Windows 10 PCs to remain dangerously unpatched against actively exploited vulnerabilities for several months this year.

By far the most curious security weakness Microsoft disclosed today has the snappy name of CVE-2024-43491, which Microsoft says is a vulnerability that led to the rolling back of fixes for some vulnerabilities affecting “optional components” on certain Windows 10 systems produced in 2015. Those include Windows 10 systems that installed the monthly security update for Windows released in March 2024, or other updates released until August 2024.

Satnam Narang, senior staff research engineer at Tenable, said that while the phrase “exploitation detected” in a Microsoft advisory normally implies the flaw is being exploited by cybercriminals, it appears labeled this way with CVE-2024-43491 because the rollback of fixes reintroduced vulnerabilities that were previously know to be exploited.

“To correct this issue, users need to apply both the September 2024 Servicing Stack Update and the September 2024 Windows Security Updates,” Narang said.

Kev Breen, senior director of threat research at Immersive Labs, said the root cause of CVE-2024-43491 is that on specific versions of Windows 10, the build version numbers that are checked by the update service were not properly handled in the code.

“The notes from Microsoft say that the ‘build version numbers crossed into a range that triggered a code defect’,” Breen said. “The short version is that some versions of Windows 10 with optional components enabled was left in a vulnerable state.”

Zero Day #1 this month is CVE-2024-38226, and it concerns a weakness in Microsoft Publisher, a standalone application included in some versions of Microsoft Office. This flaw lets attackers bypass Microsoft’s “Mark of the Web,” a Windows security feature that marks files downloaded from the Internet as potentially unsafe.

Zero Day #2 is CVE-2024-38217, also a Mark of the Web bypass affecting Office. Both zero-day flaws rely on the target opening a booby-trapped Office file.

Security firm Rapid7 notes that CVE-2024-38217 has been publicly disclosed via an extensive write-up, with exploit code also available on GitHub.

According to Microsoft, CVE-2024-38014, an “elevation of privilege” bug in the Windows Installer, is also being actively exploited.

June’s coverage of Microsoft Patch Tuesday was titled “Recall Edition,” because the big news then was that Microsoft was facing a torrent of criticism from privacy and security experts over “Recall,” a new artificial intelligence (AI) feature of Redmond’s flagship Copilot+ PCs that constantly takes screenshots of whatever users are doing on their computers.

At the time, Microsoft responded by suggesting Recall would no longer be enabled by default. But last week, the software giant clarified that what it really meant was that the ability to disable Recall was a bug/feature in the preview version of Copilot+ that will not be available to Windows customers going forward. Translation: New versions of Windows are shipping with Recall deeply embedded in the operating system.

It’s pretty rich that Microsoft, which already collects an insane amount of information from its customers on a near constant basis, is calling the Recall removal feature a bug, while treating Recall as a desirable feature. Because from where I sit, Recall is a feature nobody asked for that turns Windows into a bug (of the surveillance variety).

When Redmond first responded to critics about Recall, they noted that Recall snapshots never leave the user’s system, and that even if attackers managed to hack a Copilot+ PC they would not be able to exfiltrate on-device Recall data.

But that claim rang hollow after former Microsoft threat analyst Kevin Beaumont detailed on his blog how any user on the system (even a non-administrator) can export Recall data, which is just stored in an SQLite database locally.

As it is apt to do on Microsoft Patch Tuesday, Adobe has released updates to fix security vulnerabilities in a range of products, including Reader and Acrobat, After Effects, Premiere Pro, Illustrator, ColdFusion, Adobe Audition, and Photoshop. Adobe says it is not aware of any exploits in the wild for any of the issues addressed in its updates.

Seeking a more detailed breakdown of the patches released by Microsoft today? Check out the SANS Internet Storm Center’s thorough list. People responsible for administering many systems in an enterprise environment would do well to keep an eye on AskWoody.com, which often has the skinny on any wonky Windows patches that may be causing problems for some users.

As always, if you experience any issues applying this month’s patch batch, consider dropping a note in the comments here about it.

 

 

Read More

Cisco Releases Security Updates for Cisco Smart Licensing Utility

 ​Cisco released security updates to address two vulnerabilities (CVE-2024-20439 and CVE-2024-20440) in Cisco Smart Licensing Utility. A cyber threat actor could exploit one of these vulnerabilities to take control of an affected system. 
CISA encourages users and administrators to review the following advisory and apply the necessary updates: 

Cisco Smart Licensing Utility Vulnerabilities 

Cisco released security updates to address two vulnerabilities (CVE-2024-20439 and CVE-2024-20440) in Cisco Smart Licensing Utility. A cyber threat actor could exploit one of these vulnerabilities to take control of an affected system. 

CISA encourages users and administrators to review the following advisory and apply the necessary updates: 

Cisco Smart Licensing Utility Vulnerabilities
 Read More

Microsoft Releases September 2024 Security Updates

 ​Microsoft released security updates to address vulnerabilities in multiple products. A cyber threat actor could exploit some of these vulnerabilities to take control of an affected system.
CISA encourages users and administrators to review the following and apply necessary updates:

Microsoft Security Update Guide for September 

Microsoft released security updates to address vulnerabilities in multiple products. A cyber threat actor could exploit some of these vulnerabilities to take control of an affected system.

CISA encourages users and administrators to review the following and apply necessary updates:

Microsoft Security Update Guide for September
 Read More

CISA Adds Four Known Exploited Vulnerabilities to Catalog

 ​CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities Catalog, based on evidence of active exploitation.

CVE-2024-38226 Microsoft Publisher Security Feature Bypass Vulnerability
CVE-2024-43491 Microsoft Windows Update Remote Code Execution Vulnerability
CVE-2024-38014 Microsoft Windows Installer Privilege Escalation Vulnerability
CVE-2024-38217 Microsoft Windows Mark of the Web (MOTW) Security Feature Bypass Vulnerability

These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.
Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the Known Exploited Vulnerabilities Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information.
Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. 

CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities Catalog, based on evidence of active exploitation.

CVE-2024-38226 Microsoft Publisher Security Feature Bypass Vulnerability
CVE-2024-43491 Microsoft Windows Update Remote Code Execution Vulnerability
CVE-2024-38014 Microsoft Windows Installer Privilege Escalation Vulnerability
CVE-2024-38217 Microsoft Windows Mark of the Web (MOTW) Security Feature Bypass Vulnerability

These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.

Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the Known Exploited Vulnerabilities Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information.

Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

 Read More

Ivanti Releases Security Updates for Endpoint Manager, Cloud Service Application, and Workspace Control

 ​Ivanti released security updates to address multiple vulnerabilities in Ivanti Endpoint Manager, Cloud Service Application 4.6, and Workspace Control. A cyber threat actor could exploit some of these vulnerabilities to take control of an affected system. 
CISA encourages users and administrators to review the following Ivanti advisories and apply the necessary guidance and updates: 

Ivanti Endpoint Manager
Ivanti Cloud Service Application 4.6
Ivanti Workspace Control 

Ivanti released security updates to address multiple vulnerabilities in Ivanti Endpoint Manager, Cloud Service Application 4.6, and Workspace Control. A cyber threat actor could exploit some of these vulnerabilities to take control of an affected system. 

CISA encourages users and administrators to review the following Ivanti advisories and apply the necessary guidance and updates: 

Ivanti Endpoint Manager
Ivanti Cloud Service Application 4.6
Ivanti Workspace Control
 Read More

Rockwell Automation SequenceManager

 ​View CSAF
1. EXECUTIVE SUMMARY

CVSS v4 8.7
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Rockwell Automation
Equipment: SequenceManager
Vulnerabilities: Unquoted Search Path or Element

2. RISK EVALUATION
Successful exploitation of these vulnerabilities could cause a denial-of-service condition.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following versions of SequenceManager, a logix controller-based batch and sequencing solution, are affected:

SequenceManager: Versions prior to 2.0

3.2 Vulnerability Overview
3.2.1 Unquoted Search Path or Element CWE-428
An input validation vulnerability exists in the affected products which could allow a malicious user to send malformed packets to the server and cause a denial-of-service condition. If exploited, the device would become unresponsive, and a manual restart will be required for recovery. Additionally, if exploited, there could be a loss of view for the downstream equipment sequences in the controller. Users would not be able to view the status or command the equipment sequences, however the equipment sequence would continue to execute uninterrupted.
CVE-2024-4609 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
A CVSS v4 score has also been calculated for CVE-2024-4609. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER
Rockwell Automation reported these vulnerabilities to CISA.
4. MITIGATIONS
Rockwell Automation recommends users upgrade to version 2.0 or greater.
There is no fix available for these vulnerabilities in the affected software versions prior to v2.0. Users using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices, where possible.

Security Best Practices

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.
5. UPDATE HISTORY

September 10, 2024: Initial Publication 

View CSAF

1. EXECUTIVE SUMMARY

CVSS v4 8.7
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Rockwell Automation
Equipment: SequenceManager
Vulnerabilities: Unquoted Search Path or Element

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could cause a denial-of-service condition.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of SequenceManager, a logix controller-based batch and sequencing solution, are affected:

SequenceManager: Versions prior to 2.0

3.2 Vulnerability Overview

3.2.1 Unquoted Search Path or Element CWE-428

An input validation vulnerability exists in the affected products which could allow a malicious user to send malformed packets to the server and cause a denial-of-service condition. If exploited, the device would become unresponsive, and a manual restart will be required for recovery. Additionally, if exploited, there could be a loss of view for the downstream equipment sequences in the controller. Users would not be able to view the status or command the equipment sequences, however the equipment sequence would continue to execute uninterrupted.

CVE-2024-4609 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2024-4609. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Rockwell Automation reported these vulnerabilities to CISA.

4. MITIGATIONS

Rockwell Automation recommends users upgrade to version 2.0 or greater.

There is no fix available for these vulnerabilities in the affected software versions prior to v2.0. Users using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices, where possible.

Security Best Practices

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

September 10, 2024: Initial Publication
 Read More

Citrix Releases Security Updates for Citrix Workspace App for Windows

 ​Citrix released security updates to address multiple vulnerabilities in the Citrix Workspace App for Windows. A cyber threat actor could exploit some of these vulnerabilities to take control of an affected system. 
CISA encourages users and administrators to review the following and apply necessary updates: 

Citrix Workspace app for Windows Security Bulletin for CVE-2024-7889 and CVE-2024-7890 

Citrix released security updates to address multiple vulnerabilities in the Citrix Workspace App for Windows. A cyber threat actor could exploit some of these vulnerabilities to take control of an affected system. 

CISA encourages users and administrators to review the following and apply necessary updates: 

Citrix Workspace app for Windows Security Bulletin for CVE-2024-7889 and CVE-2024-7890
 Read More

Viessmann Climate Solutions SE Vitogate 300

 ​View CSAF
1. EXECUTIVE SUMMARY

CVSS v4 9.3
ATTENTION: Exploitable remotely/low attack complexity/public exploits are available
Vendor: Viessmann Climate Solutions SE
Equipment: Vitogate 300
Vulnerabilities: Use of Hard-coded Credentials, Forced Browsing, Command Injection

2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an attacker to achieve remote code execution.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following versions of Viessmann Climate Solutions SE Vitogate 300, a solution to connecting boilers and heat pumps to a building management system, are affected:

Viessmann Vitogate 300: Versions 2.1.3.0 and prior

3.2 Vulnerability Overview
3.2.1 Use of Hard-coded Credentials CWE-798
In Viessmann Vitogate 300 versions 2.1.3.0 and prior there is a vulnerability that affects the function isValidUser of the file /cgi-bin/vitogate.cgi of the component Web Management Interface. The manipulation leads to use of hard-coded password.
CVE-2023-5222 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2023-5222. A base score of 9.3 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.2 Direct Request (‘Forced Browsing’) CWE-425
In Viessmann Vitogate 300 versions 2.1.3.0 and prior there is a vulnerability in some unknown functionality of the file /cgi-bin/. The manipulation leads to direct request.
CVE-2023-5702 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
A CVSS v4 score has also been calculated for CVE-2023-5702. A base score of 7.1 has been calculated; the CVSS vector string is (CVSS4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).
3.2.3 Improper Neutralization of Special Elements used in a Command (‘Command Injection’) CWE-77
In Viessman Vitogate 300 versions 2.1.3.0 and prior, /cgi-bin/vitogate.cgi allows an unauthenticated attacker to bypass authentication and execute arbitrary commands via shell metacharacters in the ipaddr params JSON data for the put method.
CVE-2023-45852 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2023-45852. A base score of 9.3 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities
COUNTRIES/AREAS DEPLOYED: Worldwide

COMPANY HEADQUARTERS LOCATION: United States
3.4 RESEARCHER

CISA discovered a public Proof of Concept (PoC) as authored by ByteHunter and reported it to Viessmann.
4. MITIGATIONS
Viessmann Climate Solutions SE recommends customers update to version 3.0.0.0 to fix these vulnerabilities. The software is available to download at their (website)
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.
5. UPDATE HISTORY

September 10, 2024: Initial Publication 

View CSAF

1. EXECUTIVE SUMMARY

CVSS v4 9.3
ATTENTION: Exploitable remotely/low attack complexity/public exploits are available
Vendor: Viessmann Climate Solutions SE
Equipment: Vitogate 300
Vulnerabilities: Use of Hard-coded Credentials, Forced Browsing, Command Injection

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to achieve remote code execution.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Viessmann Climate Solutions SE Vitogate 300, a solution to connecting boilers and heat pumps to a building management system, are affected:

Viessmann Vitogate 300: Versions 2.1.3.0 and prior

3.2 Vulnerability Overview

3.2.1 Use of Hard-coded Credentials CWE-798

In Viessmann Vitogate 300 versions 2.1.3.0 and prior there is a vulnerability that affects the function isValidUser of the file /cgi-bin/vitogate.cgi of the component Web Management Interface. The manipulation leads to use of hard-coded password.

CVE-2023-5222 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2023-5222. A base score of 9.3 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.2 Direct Request (‘Forced Browsing’) CWE-425

In Viessmann Vitogate 300 versions 2.1.3.0 and prior there is a vulnerability in some unknown functionality of the file /cgi-bin/. The manipulation leads to direct request.

CVE-2023-5702 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2023-5702. A base score of 7.1 has been calculated; the CVSS vector string is (CVSS4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.2.3 Improper Neutralization of Special Elements used in a Command (‘Command Injection’) CWE-77

In Viessman Vitogate 300 versions 2.1.3.0 and prior, /cgi-bin/vitogate.cgi allows an unauthenticated attacker to bypass authentication and execute arbitrary commands via shell metacharacters in the ipaddr params JSON data for the put method.

CVE-2023-45852 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2023-45852. A base score of 9.3 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities
COUNTRIES/AREAS DEPLOYED: Worldwide

COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

CISA discovered a public Proof of Concept (PoC) as authored by ByteHunter and reported it to Viessmann.

4. MITIGATIONS

Viessmann Climate Solutions SE recommends customers update to version 3.0.0.0 to fix these vulnerabilities. The software is available to download at their (website)

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

September 10, 2024: Initial Publication
 Read More

BPL Medical Technologies PWS-01-BT and BPL Be Well Android Application

 ​View CSAF
1. EXECUTIVE SUMMARY

CVSS v4 5.1
ATTENTION: Low attack complexity/public exploits are available
Vendor: BPL Medical Technologies
Equipment: PWS-01-BT, Be Well Android App
Vulnerability: Cleartext Transmission of Sensitive Information

2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to intercept and modify information as it being processed
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following BPL Medical Technologies products are affected:

Be Well Android Application: Versions 3.64 and prior
PWS-01-BT: Versions 3.64 and prior

3.2 Vulnerability Overview
3.2.1 Cleartext Transmission of Sensitive Information CWE-319
BPL Personal Weighing Scale PWS-01BT IND/09/18/599 devices send sensitive information in unencrypted BLE packets. (The packet data also lacks authentication and integrity protection.)
CVE-2024-34463 has been assigned to this vulnerability. A CVSS v3.1 base score of 4.6 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N).
A CVSS v4 score has also been calculated for CVE-2024-34463. A base score of 5.1 has been calculated; the CVSS vector string is (CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Healthcare and Public Health Sector
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: India

3.4 RESEARCHER
Yash Chandna reported this vulnerability to CISA.
4. MITIGATIONS
BPL Medical Technologies has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of the affected products are encouraged to contact BPL Medical Technologies support for additional information.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.
5. UPDATE HISTORY

September 10, 2024: Initial Publication 

View CSAF

1. EXECUTIVE SUMMARY

CVSS v4 5.1
ATTENTION: Low attack complexity/public exploits are available
Vendor: BPL Medical Technologies
Equipment: PWS-01-BT, Be Well Android App
Vulnerability: Cleartext Transmission of Sensitive Information

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to intercept and modify information as it being processed

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following BPL Medical Technologies products are affected:

Be Well Android Application: Versions 3.64 and prior
PWS-01-BT: Versions 3.64 and prior

3.2 Vulnerability Overview

3.2.1 Cleartext Transmission of Sensitive Information CWE-319

BPL Personal Weighing Scale PWS-01BT IND/09/18/599 devices send sensitive information in unencrypted BLE packets. (The packet data also lacks authentication and integrity protection.)

CVE-2024-34463 has been assigned to this vulnerability. A CVSS v3.1 base score of 4.6 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N).

A CVSS v4 score has also been calculated for CVE-2024-34463. A base score of 5.1 has been calculated; the CVSS vector string is (CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Healthcare and Public Health Sector
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: India

3.4 RESEARCHER

Yash Chandna reported this vulnerability to CISA.

4. MITIGATIONS

BPL Medical Technologies has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of the affected products are encouraged to contact BPL Medical Technologies support for additional information.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.

5. UPDATE HISTORY

September 10, 2024: Initial Publication
 Read More

iniNet Solutions SpiderControl SCADA Web Server

 ​View CSAF
1. EXECUTIVE SUMMARY

CVSS v4 8.7
ATTENTION: Exploitable remotely/low attack complexity
Vendor: iniNet Solutions GmbH
Equipment: SpiderControl SCADA Web Server
Vulnerabilities: Unrestricted Upload of File with Dangerous Type

2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to log in or execute arbitrary code.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following versions of SpiderControl, an HMI program, are affected:

SpiderControl SCADA Web Server: Versions v2.09 and prior

3.2 Vulnerability Overview
3.2.1 Unrestricted Upload of File with Dangerous Type CWE-434
SpiderControl SCADA Web Server has a vulnerability that could allow an attacker to upload specially crafted malicious files without authentication.
CVE-2024-8232 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).
A CVSS v4 score has also been calculated for CVE-2024-8232. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N).
3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Switzerland

3.4 RESEARCHER
elcazators ELEX FEIGONG RESEARCH INSTITUTE of Elex CyberSecurity, Inc reported this vulnerability to CERT/CC.
4. MITIGATIONS
IniNet Solutions has released a new version of SpiderControl SCADA Server, (3.2.2), to address this issue. It can be found at the following location: https://spidercontrol.net/download/download-area-2/?lang=en
IniNet Solutions reminds users that the webserver is designed to be used in a protected environment. IniNet Solutions GmbH recommends that users never connect control system software directly to the Internet. If a user must connect to the Internet, IniNet Solutions GmbH recommends using a managed infrastructure to do so.
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.
5. UPDATE HISTORY

September 10, 2024: Initial Publication 

View CSAF

1. EXECUTIVE SUMMARY

CVSS v4 8.7
ATTENTION: Exploitable remotely/low attack complexity
Vendor: iniNet Solutions GmbH
Equipment: SpiderControl SCADA Web Server
Vulnerabilities: Unrestricted Upload of File with Dangerous Type

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to log in or execute arbitrary code.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of SpiderControl, an HMI program, are affected:

SpiderControl SCADA Web Server: Versions v2.09 and prior

3.2 Vulnerability Overview

3.2.1 Unrestricted Upload of File with Dangerous Type CWE-434

SpiderControl SCADA Web Server has a vulnerability that could allow an attacker to upload specially crafted malicious files without authentication.

CVE-2024-8232 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).

A CVSS v4 score has also been calculated for CVE-2024-8232. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Switzerland

3.4 RESEARCHER

elcazators ELEX FEIGONG RESEARCH INSTITUTE of Elex CyberSecurity, Inc reported this vulnerability to CERT/CC.

4. MITIGATIONS

IniNet Solutions has released a new version of SpiderControl SCADA Server, (3.2.2), to address this issue. It can be found at the following location: https://spidercontrol.net/download/download-area-2/?lang=en

IniNet Solutions reminds users that the webserver is designed to be used in a protected environment. IniNet Solutions GmbH recommends that users never connect control system software directly to the Internet. If a user must connect to the Internet, IniNet Solutions GmbH recommends using a managed infrastructure to do so.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

September 10, 2024: Initial Publication